Column address hold time
tCAH
10
10
ns
Column address hold referenced to /RAS
tAR
40
45
ns
Column Address to /RAS lead time
tRAL
25
30
ns
Read command set-up time
tRCS
0
0
ns
Read command hold referenced to /CAS
tRCH
0
0
ns
Read command hold referenced to /RAS
tRRH
0
0
ns
Write command hold time
tWCH
10
10
ns
Write command hold referenced to /RAS
tWCR
40
45
ns
Write command pulse width
tWP
10
10
ns
Write command to /RAS lead time
tRWL
15
15
ns
Write command to /CAS lead time
tCWL
13
15
ns
Data-in set-up time
tDS
0
0
ns
Data-in hold time
tDH
10
15
ns
Data-in hold referenced to /RAS
tDHR
40
45
ns
Refresh period 2K Ref.
tREF
32
32
ns
Write command set-up time
tWCS
0
0
ns
/CAS setup time (C-B-R refresh)
tCSR
5
5
ns
/CAS hold time (C-B-R refresh)
tCHR
10
10
ns
/RAS precharge to /CAS hold time
tRPC
5
5
ns
Access time from /CAS precharge
tCPA
30
35
ns
Fast page mode cycle time
tPC
35
40
ns
/CAS precharge time (Fast page)
tCP
10
10
ns
/RAS pulse width (Fast page )
tRASP
50
200K
60
200K
ns
/W to /RAS precharge time (C-B-R refresh)
tWRP
10
10
ns
/W to /RAS hold time (C-B-R refresh)
tWRH
10
10
ns
/CAS precharge(C-B-R counter test)
tCPT
20
20
ns
NOTES
1.An initial pause of 200µs is required after power-up followed by any 8 /RAS-only or /CAS-before-/RAS refresh cycles
before proper device operation is achieved.
2.VIH (min) and VIL (max) are reference levels for measuring timing of input signals. Transition times are measured between
VIH(min) and VIL(max) and are assumed to be 5ns for all inputs.
3.Measured with a load equivalent to 2TTL loads and 100pF
4.Operation within the tRCD(max) limit insures that tRAC(max) can be met. tRCD(max) is specified as a reference point only. If tRCD
is greater than the specified tRCD(max) limit, then access time is controlled exclusively by tCAC.
5.Assumes that tRCD ≥ tRCD(max)
6. tAR, tWCR, tDHR are referenced to tRAD(max)
7.This parameter defines the time at which the output achieves the open circuit condition and is not referenced to VOH or
VOL.
8. tWCS, tRWD, tCWD and tAWD are non restrictive operating parameter.
They are included in the data sheet as electrical characteristic only. If tWCS ≥ tWCS(min) the cycle is an early write
URL: www.hbe.co.kr
REV.1.0. (August. 2002)
5