English
Language : 

HE3321A0400 Datasheet, PDF (2/2 Pages) HAMLIN Position and Movement Sensor Solutions – HE3300 S.I.L Relay Features and Benefits
Table 2 HE3300 Series
Column Number
Contact Type
Relay Types
CONTACT RATINGS Power, Switching
Contact Hamlin Voltage, Switching
for specific
Current, Switching
load/life details
Current, Carry
Recognised File #E47258 Electrical and Operating Characteristics @ 25˚C.
1
2
3
4
5
Form A
SPST-NO
Standard
Form A
SPST-NO
High
Voltage
Form A
SPST-NO
Power
Switching
Form C
SPST-CO
Standard
Form B
SPST-NC
Standard
HE3321A HE3351A HE3361A HE3321C, E HE3321B
Watt - max.
Vdc - max.
A - max.
A - max.
10
10
50
5
10
200
300
200
175
200
0.5
1.0
1.5
0.25
0.5
1.2
1.5
2.0
1.5
1.2
VOLTAGE
HOLD-OFF
RESISTANCE
TIMING
ENVIRONMENTAL
Across Open Contacts
Contacts to Coil
Vdc - min.
Vac - min.
Contact, Initial
Ω - max.
Insulation:Across Open Contacts
Ω - min.
Between Isolated Terminals Ω - min.
Operate Time
Release Time
ms - max.
ms - max.
Temperature, Operating
Temperature, Storage
Vibration Resistance
Shock Resistance
°C
°C
G - max.
10-2000 Hz.
G - max.
11 ms, 1⁄2 sine
250
450
300
200
250
2500
2500
2500
2500
2500
0.150
1010
1010
1.0
1.0
-40 to +85
-40 to +105
20
0.150
1010
1010
1.0
1.0
-20 to +85
-40 to +105
20
0.150
1010
1010
1.0
1.0
-40 to +85
-40 to +105
20
0.200
109
1010
3.0
3.0
-40 to +85
-40 to +105
20
0.150
1010
1010
1.0
1.0
-40 to +85
-40 to+ 105
20
50
50
50
50
50
Table 3 HE3300 Series Relay
Contact Form Electrical & Dimensions
& Type
Operating
Characteristics
Part
Number
Nominal
Coil Voltage
Vdc
Coil
Resistance
±10% Ohms
Coil Characteristics @ 25˚C.
Must
Operate
Vdc
Must Maximum Top View 2,54 mm, 0.1 in. Grid
Release Coil Voltage
Dot on Case: Pin 1
Vdc
Vdc
Numbers not printed on case.
1A
HE3321A0400
5
500
3.75
0.5
22
SPST-NO
See Table 2 See Figure 1 HE3321A1200
12
Column 1
HE3321A2400
24
500
9.0
1.0
22
2000
18.0
2.0
44
See Note 1, 2
1B
HE3321B0400
5
500
3.75
0.5
6.5
SPST-NC
See Table 2 See Figure 1 HE3321B1200
12
Column 5
HE3321B2400
24
500
9.0
1.0
14.0
2000
18.0
2.0
28.0
1C
HE3321C0500
5
SPDT-CO
See Table 2 See Figure 2 HE3321C1200
12
Column 4
HE3321C2400
24
125
3.75
0.5
11
500
9.0
1.0
22
2000
18.0
2.0
44
1C
HE3321E0500
5
SPDT-CO
See Table 2 See Figure 3 HE3321E1200
12
Column 4
HE3321E2400
24
125
3.75
0.5
11
500
9.0
1.0
22
2000
18.0
2.0
44
1A
HE3351A0500
5
SPST-NO
See Table 2 See Figure 1 HE3351A1200
12
Column 2
High Voltage
HE3351A2400
24
125
3.75
0.5
11
500
9.0
1.0
22
2000
18.0
2.0
44
1A
HE3361A0500
5
SPST-NO
See Table 2 See Figure 1 HE3361A1200
12
Column 3
Power Switching
HE3361A2400
24
125
3.75
0.5
11
500
9.0
1.0
22
2000
18.0
2.0
44
Notes:
1) HE3321B - Exceeding recommended voltage may cause
contact reclosure.
2) External magnetic shielding not available on 12 and
24 Volt Form B relays.
INFORMATION PROVIDED ON THIS DATA SHEET IS PROVIDED FOR INFORMATION PURPOSES ONLY AND SHOULD NOT BE RELIED
UPON AS BEING ACCURATE FOR ANY PARTICULAR PURPOSE. Product performance may be affected by the application to which the product
is put. Upon request, HAMLIN will assist purchasers by providing information specific to any particular application. HAMLIN disclaims any and all
liability whatsoever for any purchaser’s reliance upon the information contained on this data sheet without further consultation with authorised
representatives of HAMLIN.
53