English
Language : 

59630-1-T-01-A Datasheet, PDF (1/1 Pages) HAMLIN Position and Movement Sensor Solutions – Float Sensor Features and Benefits
DIMENSIONS (in) mm
59630 Float Sensor Features and Benefits
Features
Benefits
• Sensor with integral float magnet
attached
• Sensor operates when float rises
from end stop position
• Choice of contacts
• Choice of connector
• Customer defined cable length
• No standby power required
• Hermetically sealed, magnetically
operated contacts continue to
operate long after optical and other
technologies fail due to
contamination
• Simple installation with M8 thread
and nut
www.hamlin.com
Applications
• Liquid level control
• Air conditioning systems
• Industrial Process Control
CUSTOMER OPTIONS - Switching Specifications
TABLE 1
Contact Type
Switch Type
Voltage
Current
Resistance
Capacitance
Temperature
Time
Shock
Vibration
Power
Switching
Breakdown
Switching
Carry
Contact, Initial
Insulation
Contact
Operating
Storage
Operate
Release
11ms 1⁄2 sine
50-2000 Hz
Form A
Watt - max.
Vdc - max.
Vdc - min.
A - max.
A - max.
Ω - max.
Ω - min.
pF - typ.
°C
°C
ms - max.
ms - max.
G - max.
G - max.
Normally
Open
1
10
200
250
0.5
1.2
0.2
1010
0.3
-40 to +105
-50 to +105
1.0
1.0
100
30
Normally Open
High Voltage
2
10
300
450
0.5
1.5
0.2
1010
0.2
-20 to +105
-50 to +105
1.0
1.0
100
30
Change
Over
3
5
175
200
0.25
1.5
0.2
109
0.3
-40 to +105
-50 to +105
3.0
3.0
50
30
Normally
Closed
4
10
200
250
0.5
1.2
0.2
1010
0.3
-40 to +105
-50 to +105
1.0
1.0
100
30
CUSTOMER OPTIONS - Cable Length and Termination Specification
TABLE 2
Cable Type:-
24 AWG 7/32 PVC 105oC
UL1430/UL1569
Standard Lengths
SELECT
OPTION
CABLE
LENGTH
(in) mm
01
(3,94) 100
02
(11,81) 300
TABLE 3
Termination Options:-
SELECT
OPTION
DESCRIPTION
(2 WIRE VERSIONS ILLUSTRATED)
A or F Tinned or untinned leads
B
Crimped terminals
C
6.35mm fastons
ACTIVATION
03
(19,69) 500
04
(29,53) 750
05
(39,37) 1000
D
AMP MTE 2.54mm pitch
E
JST XHP 2.5mm pitch
ORDERING INFORMATION
5906360
X
T
Series 59630
Switch Type
Sensitivity
Cable Length
Termination
Table 1
Table 2
Table 3
Hamlin USA Tel: +1 920 648 3000 • Fax: +1 920 648 3001 • Email: sales.us@hamlin.com
Hamlin UK
Tel: +44 (0)1379 649700 • Fax: +44 (0)1379 649702 • Email: sales.uk@hamlin.com
Hamlin Germany Tel: +49 (0) 6181 953660 • Fax: +49 (0) 6181 9536666 • Email: sales.de@hamlin.com
Hamectrol France Tel: +33 (0) 1 4687 0202 • Fax: +33 (0) 1 4686 6786 • Email: sales.fr@hamlin.com
ISSUE No: 4 DATE: 1/5/3
41
Using sensor with float magnet orientated as
illustrated below
XX
X
DETAILS PROVIDED ON THIS DATA SHEET ARE PROVIDED FOR
INFORMATION PURPOSES ONLY AND SHOULD NOT BE RELIED
UPON AS BEING ACCURATE FOR ANY PARTICULAR PURPOSE.
Product performance may be affected by the application to which the
product is put. Upon request, HAMLIN will assist purchasers by
providing information specific to any particular application. HAMLIN
disclaims any and all liability whatsoever for any purchaser’s reliance
upon the information contained on this data sheet without further
consultation with authorised representatives of HAMLIN.