59025-010 Datasheet, PDF (1/1 Pages) HAMLIN Position and Movement Sensor Solutions – 59025 Firecracker Features and Benefits
File E61760(N)
Actuator
Sensor
DIMENSIONS (in) mm
59025 Firecracker Features and Benefits
Features
Benefits
• 2 part magnetically operated
proximity sensor
• UL recognised
• Choice of normally open, normally
closed or change over contacts
• Customer defined sensitivity
• Choice of cable length and
connector
• Quick and easy to install
• No standby power requirement
• Operates through non-ferrous
materials such as wood, plastic or
aluminium
• Hermetically sealed, magnetically
operated contacts continue to
operate long after optical and other
technologies fail due to
contamination
www.hamlin.com
Applications
• Position and limit sensing
• Security
• Level sensing
• Linear actuators
57025
59025
A
Max
(.245) 6,22
(.245) 6,22
B
Max
(1.000) 25,40
(1.000) 25,40
C
NOM.
-
Table 3 ± (.393) 10,00
CUSTOMER OPTIONS - Switching Specifications
TABLE 1
Contact Type
Switch Type
Voltage
Current
Resistance
Capacitance
Temperature
Time
Shock
Vibration
Power
Switching
Breakdown
Switching
Carry
Contact, Initial
Insulation
Contact
Operating
Storage
Operate
Release
11ms 1⁄2 sine
50-2000 Hz
Form A
Watt - max.
Vdc - max.
Vdc - min.
A - max.
A - max.
Ω - max.
Ω - min.
pF - typ.
°C
°C
ms - max.
ms - max.
G - max.
G - max.
Normally
Open
1
10
200
250
0.5
1.2
0.2
1010
0.3
-40 to +105
-65 to +105
1.0
1.0
100
30
Normally Open
High Voltage
2
10
300
450
0.5
1.5
0.2
1010
0.2
-20 to +105
-65 to +105
1.0
1.0
100
30
Change
Over
3
5
175
200
0.25
1.5
0.2
109
0.3
-40 to +105
-65 to +105
3.0
3.0
50
30
Normally
Closed
4
5
175
200
0.25
1.5
0.2
109
0.3
-40 to +105
-65 to +105
3.0
3.0
50
30
CUSTOMER OPTIONS - Sensitivity, Cable Length and Termination Specification
TABLE 2
Sensitivity Options:-
Activate Distances are approximate
using Hamlin 57025 actuator
as illustrated
Switch AT before modification
Select Option
Switch
Type
1 Normally Open
2 High Voltage
3 Change Over
4 Normally Closed
S
Pull In
RAanTge
Activate
Distance
d
(in) mm
12-18 (.315)
8.0
(.276)
15-20
7.0
T
Pull In
RaAnTge
Activate
Distance
d
(in) mm
(.236)
17-23
6.0
(.216)
20-25
5.5
U
Pull In
RaAnTge
Activate
Distance
d
(in) mm
(.197)
22-28
5.0
(.177)
25-30
4.5
V
Pull In
RaAnTge
Activate
Distance
d
(in) mm
(.157)
27-33
4.0
TABLE 3
Cable Type:-
24 AWG 7/32 PVC 105oC
UL1430/UL1569
Standard Lengths
SELECT
CABLE
OPTION
LENGTH
(in) mm
01
(3.94 )100
02
(11.81) 300
03
(19,69) 500
04
(29,53) 750
05
(39,37)1000
TABLE 4
Termination Options:-
SELECT
OPTION
A
DESCRIPTION
(2 WIRE VERSIONS ILLUSTRATED)
Tinned leads (3.8±0.76)mm
F Untinned leads (6.4±0.76)mm
ORDERING INFORMATION
N.B. 57025 actuator sold separately
5903265
X
XT
XX
X
Series 59025
Switch Type
Sensitivity
Cable Length
Termination
Table 1
Table 2
Table 23
Table 34
Hamlin USA Tel: +1 920 648 3000 • Fax: +1 920 648 3001 • Email: sales.us@hamlin.com Hamlin
UK
Tel: +44 (0)1379 649700 • Fax: +44 (0)1379 649702 • Email: sales.uk@hamlin.com
Hamlin Germany Tel: +49 (0) 6142 923920 • Fax: +49 (0) 6142 923921 • Email: sales.de@hamlin.com
Hamectrol France Tel: +33 (0) 1 6047 3000 • Fax: +33 (0) 1 6015 9136 • Email: sales.fr@hamlin.com
Issue No.: 5 DCR No.: B8163
Issue: Flash Du Date: 9/26/2011
22
DETAILS PROVIDED ON THIS DATA SHEET ARE PROVIDED FOR
INFORMATION PURPOSES ONLY AND SHOULD NOT BE RELIED
UPON AS BEING ACCURATE FOR ANY PARTICULAR PURPOSE.
Product performance may be affected by the application to which the
product is put. Upon request, HAMLIN will assist purchasers by
providing information specific to any particular application. HAMLIN
disclaims any and all liability whatsoever for any purchaser’s reliance
upon the information contained on this data sheet without further
consultation with authorised representatives of HAMLIN.