English
Language : 

55110-3M-01-A Datasheet, PDF (1/1 Pages) HAMLIN Position and Movement Sensor Solutions – L.E.D. Flange Mount Hall Effect Sensor Features and Benefits
www.hamlin.com
55110 L.E.D. Flange Mount Hall Effect Sensor Features and Benefits
Features
• Magnetically operated position sensor
• Digital or latching types available
• Integral LED
• Medium or high senstivities
• 3 wire (voltage output)
• Vibration 50g max. @ 50-2,000Hz
• Shock 150g max. @ 11ms 1/2 Sine
• EMC to DIN 40839 (Consult Hamlin)
• Reverse/Over Voltage Protection
• Built in temperature compensation
Benefits
• High switching speed up to 10kHz
• Long life; up to 20 billion operations
• Visual indication of operation
• Unaffected by harsh environments
• Operates in static or dynamic magnetic
field
• Customer selection of cable length and
connector type
Applications
• Position and limit sensing
• RPM measurement
• Flow metering
• Commutation of brushless dc motors
• Angle sensing
• Magnetic encoders
DIMENSIONS (in) mm
BLOCK DIAGRAMS
Note
Add capacitor Cn as
shown, close for the
sensor, for transient
suppression if required
CUSTOMER OPTIONS - Switching Specifications
SPECIFICATIONS
Hall Type
Supply Voltage
(Note 1)
Absolute Ratings
Operate
Overvoltage Protection
Vdc
Vdc
Vdc-max
Output High Voltage
Vdc-min
Output Low Voltage
Vdc-max
Output Current (continuously on)
mA-max
Switching Speed
kHz-max
Operating
OC
Temperature
Storage
OC
Note 1 - As long as Tj (Junction Temperature) max. is not exceeded
Digital Switch or Digital Latch
3 Wire
(Voltage output)
-15 to +28
+3.8 to +24
32
Vdd-2 @ 0.1mA (sinking output with internal pull-up)
0.4 @ 20mA
20
10
-40 to +85
-65 to +85
CUSTOMER OPTIONS - Sensitivity, Cable Length and Termination Specification
TABLE 1
HALL OPTIONS
ACTIVATE DISTANCES ARE APPROXIMATE
USING NEFEB MAGNET
(.827L X .276W X .185H) 21 X 7 X 4.7
HAMLIN P/N 5812334000
d
NS
TABLE 2
Cable Length:-
(Cable type 24 AWG 7/32 PVC
105oC Double Insulated)
SELECT
OPTION
LENGTH
(in) mm
TABLE 3
Termination Options:-
SELECT
OPTION
DESCRIPTION
A
Tinned leads
Select
Hall Option
3M
3H
Hall
Type
3 Wire Switch
3 Wire Switch
Sensitivity
Gauss (Typ.)
130
59
Activate - d
(in) mm
(.492) 12.5
(.709) 18.0
01
(3.94) 100
02
(11.81) 300
03
(19.69) 500
04
(29.53) 750
B
Crimped terminals
C
6.35mm fastons
D
AMP MTE 2.54mm pitch
3L
3 Wire Latch
86
(.394) 10.0
05
(39.37) 1000
E
JST XHP 2.5mm pitch
ORDERING INFORMATION
55110 XX
XX
X
Series 55110
Hall option
Cable Length
Termination
Table 1
Table 2
Table 3
Hamlin USA Tel: +1 920 648 3000 • Fax: +1 920 648 3001 • Email: sales.us@hamlin.com
Hamlin UK
Tel: +44 (0)1379 649700 • Fax: +44 (0)1379 649702 • Email: sales.uk@hamlin.com
Hamlin Germany Tel: +49 (0) 6142 923920 • Fax: +49 (0) 6142 923921 • Email: sales.de@hamlin.com
Hamectrol France Tel: +33 (0) 1 4687 0202 • Fax: +33 (0) 1 4686 6786 • Email: sales.fr@hamlin.com
Issue No: AC Date:05/02/09 DCR B6092
INFORMATION PROVIDED ON THIS DATA SHEET IS PROVIDED FOR
INFORMATION PURPOSES ONLY AND SHOULD NOT BE RELIED UPON AS
BEING ACCURATE FOR ANY PARTICULAR PURPOSE. Product performance
may be affected by the application to which the product is put. Upon request,
HAMLIN will assist purchasers by providing information specific to any
particular application. HAMLIN disclaims any and all liability whatsoever for any
purchaser’s reliance upon the information contained on this data sheet without
further consultation with authorised representatives of HAMLIN.