English
Language : 

S10814_15 Datasheet, PDF (6/10 Pages) Hamamatsu Corporation – CCD area image sensors
CCD area image sensors
S10814, S10811-11
Timing chart
Pre-integration period
AC X-ray exposure
(Trigger A)*1
DC X-ray exposure
(Trigger A)*1
Trigger B (S10811-11)*2
P1V
P2V, TG*3
P1H
P2H, SG
RG
OUT
P2V, TG
Integration period
Readout period
Tpwv
VD1
1
VD: Vertical dummy
2, 3, ... , 1199, 1200, VD2
Tovr
Tpwh, Tpws
Enlarged view
P1H
P2H, SG
RG
Tpwr
OUT
S2, S3, S4, ... , S1702, S1703, S1704
D1
D2
S1
D3
D4
*1: Trigger A (S10814) is the same as AC/DC X-ray exposure form.
*2: Low active trigger pulse
*3: TG terminal can be short-circuited to P2V terminal.
KMPDC0
KMPDC0351EB
P1V, P2V, TG
Parameter
Pulse width*15
Rise and fall times
Symbol
Min.
Typ.
Max.
Unit
tpwv
30
60
-
μs
tprv, tpfv
200
-
-
ns
P1H, P2H
Pulse width
Rise and fall times*15
tpwh
100
500
tprh, tpfh
5
-
-
ns
-
ns
Duty ratio
-
-
50
-
%
Pulse width
tpws
100
500
-
ns
SG
Rise and fall times
tprs, tpfs
3
-
-
ns
Duty ratio
-
-
50
-
%
RG
Pulse width
Rise and fall times
tpwr
10
50
tprr, tpfr
3
-
-
ns
-
ns
TG-P1H
Overlap time
tovr
18
36
-
μs
*15: The clock pulses should be overlapped at 50% of maximum amplitude.