English
Language : 

G9211_15 Datasheet, PDF (6/11 Pages) Hamamatsu Corporation – Near infrared image sensors (0.9 to 1.67 m / 2.55 m)
InGaAs linear image sensors
G9211 to G9214/G9205 to G9208 Series
Timing chart
CLK
(input)
Reset
(input)
Integration
time
2 clocks
8 clocks
8 clocks
AD_trig
Video
(output)
tr(clk)
CLK
t1
tr(RES)
tf(clk)
t2
tf(RES)
1 ch
2 ch
Reset
Integration time
Actual integration time
8 × N clocks (Readout time)
10 clocks min.
(n-1) ch
n ch
Blank period
(10 clocks or more)
AD_trig
Video
Parameter
Clock pulse frequency
Clock pulse width
Clock pulse rise/fall times
Reset pulse width
Reset pulse rise/fall times
Reset (rise) timing
Reset (fall) timing
Output settling time
Reset
Output
t3
Readout time for channel 1
Readout time
for channel 2 Readout time for last channel
Symbol
Min.
Typ.
Max.
-
0.1
-
4
tpw(clk)
100
-
-
tr(clk), tf(clk)
0
20
100
tpw(RES)
6000
-
-
tr(RES), tf(RES)
0
20
100
t1
50
-
-
t2
50
-
-
t3
-
-
600
KMIRC
KMIRC0066EB
Unit
MHz
ns
ns
ns
ns
ns
ns
ns
6