English
Language : 

S12443_15 Datasheet, PDF (5/10 Pages) Hamamatsu Corporation – CMOS linear image sensor
CMOS linear image sensor
S12443
Timing chart
1234
34 35 36
CLK
Integration time
ST
thp(ST)
tlp(ST)
tpi(ST)
48 clocks
Video
2496
1
Trig
EOS
48 49 50
1 2496
50
tf(CLK)
tr(CLK)
CLK
1/f(CLK)
ST
tr(ST)
tf(ST)
thp(ST)
tpi(ST)
tlp(ST)
KMPDC0420EB
Parameter
Symbol
Min.
Typ.
Start pulse cycle*13
tpi(ST)
70/f(CLK)
-
Start pulse high period*13 *14
thp(ST)
6/f(CLK)
-
Max.
Unit
-
s
-
s
Start pulse low period
tlp(ST)
64/f(CLK)
-
-
s
Start pulse rise and fall times
tr(ST), tf(ST)
0
10
30
ns
Clock pulse duty ratio
-
45
50
55
%
Clock pulse rise and fall times
tr(CLK), tf(CLK)
0
10
30
ns
*13: Dark output increases if the start pulse cycle or the start pulse high period is lengthened.
*14: The integration time equals the high period of ST plus 34 CLK cycles.
The shift register starts operation at the rising edge of CLK immediately after ST goes low.
The integration time can be changed by changing the ratio of the high and low periods of ST.
If the first Trig pulse after ST goes low is counted as the first pulse, the Video signal is acquired at the rising edge of the 50th Trig pulse.