English
Language : 

T11262_15 Datasheet, PDF (1/4 Pages) Hamamatsu Corporation – High sensitivity for gas density measurement
Thermopile detectors
T11262 series
High sensitivity,
for gas density measurement (T11262-01),
for flame detection (T11262-06)
The T11262-01 is a high-sensitivity thermopile detector suitable for gas density measurement or the like. It uses a TO-18
package with a window having high transmittance in the 3 to 5 μm spectral band. By attaching an external band-pass filter to
the thermopile detector, customers can apply it to various types of gas density measurements. The T11262-06 employs a 4.45
μm band-pass filter and is suitable for flame detection applications.
Features
Spectral response: 3 to 5 μm (T11262-01), 4.45 μm (T11262-06)
TO-18 package
High sensitivity
Applications
Gas density measurement and the like (T11262-01)
Flame detection (T11262-06)
Absolute maximum ratings
Parameter
Operating temperature
Storage temperature
Symbol
Topr
Tstg
T11262-01
-30 to +85
-40 to +100
T11262-06
Unit
-10 to +80
°C
-20 to +85
°C
Structure
Parameter
Photosensitive area
Package
Window material
Symbol
A
-
-
Condition
T11262-01
T11262-06
Unit
1.2 × 1.2
mm
TO-18
-
AR coating Si with 3 to 5 μm
high-transmittance
4.45 μm band-pass filter
-
Electrical and optical characteristics (Ta=25 °C)
Parameter
Spectral response
Photosensitivity
Element resistance
Noise voltage
Noise equivalent power
Detectivity
Rise time
Temperature coefficient
of element resistance
Field of view
Symbol
λ
S
Re
Vn
NEP
D*
tr
TCR
FOV
Condition
1 Hz, 500 K
Johnson noise
0 to 63%
Photosensitivity 50%
T11262-01
Min. Typ. Max.
- 3 to 5 -
40
50
60
100 125 150
-
45
50
-
0.9 1.3
0.9 × 108 1.3 × 108 -
-
20
30
T11262-06
Min. Typ. Max.
-
4.45
-
40
50
60
100 125 150
-
45
50
-
0.9 1.3
0.9 × 108 1.3 × 108 -
-
20
30
-
±0.1
-
-
±0.1
-
-
90
-
-
90
-
Unit
μm
V/W
kΩ
nV/Hz1/2
nW/Hz1/2
cm∙Hz1/2/W
ms
%/°C
degrees
www.hamamatsu.com
1