English
Language : 

S11963-01CR_15 Datasheet, PDF (1/10 Pages) Hamamatsu Corporation – Distance area image sensor
Distance area image sensor
S11963-01CR
Measures the distance to an object by TOF
(Time-Of-Flight) method
The distance image sensors are designed to measure the distance to an object by TOF method. When used in combination
with a pulse modulated light source, this sensor outputs phase difference information on the timing that the light is emitted
and received. The sensor output signals are arithmetically processed by an external signal processing circuit or a PC to obtain
distance data.
Features
High-speed charge transfer structure
Wide dynamic range, low noise by non-destructive readout
Built-in column gain amplifier (gain: 1, 2 or 4 times)
Operates with minimal detection errors even under fluctuating
(charge drain function)
Real-time distance measurement
Applications
Obstacle detection (self-driving, robots, etc.)
Security (intrusion detection, etc.)
Shape recognition (logistics, robots, etc.)
Motion capture
Structure
Parameter
Image size
Pixel size
Pixel pitch
Number of pixels
Number of effective pixels
Package
Window material
Note: This product is not hermetically sealed.
Specification
4.8 × 3.6
30 × 30
30
168 × 128
160 × 120
44-pin PWB
AR-coated glass
Unit
mm
μm
μm
pixels
pixels
-
-
Absolute maximum ratings
Parameter
Symbol
Condition
Value
Unit
Analog supply voltage
Vdd(A)
Ta=25 °C
-0.3 to +6
V
Digital supply voltage
Vdd(D)
Ta=25 °C
-0.3 to +6
V
Pixel reset
Vr
Analog input terminal
voltage
Output offset
Column gain circuit
Gain selection
Vref
Vref2
sel0, sel1, sel2
Ta=25 °C
-0.3 to Vdd(A) + 0.3
V
Photosensitive area
Vpg
Frame reset pulse
reset
Digital input terminal
voltage
Frame synchronous trigger pulse
Line synchronous trigger pulse
Pixel reset pulse
vst
hst
ext_res
Ta=25 °C
-0.3 to Vdd(D) + 0.3
V
Master clock pulse
mclk
Charge transfer clock pulse voltage
VTX1, VTX2, VTX3
Ta=25 °C
-0.3 to Vdd(A) + 0.3
V
Operating temperature
Topr
No dew condensation*1
-25 to +85
°C
Storage temperature
Tstg
No dew condensation*1
-40 to +100
°C
Reflow soldering conditions*2
Tsol
260 °C max. 2 times (see P.10) -
*1: When there is a temperature difference between a product and the surrounding area in high humidity environment, dew condensation
may occur on the product surface. Dew condensation on the product may cause deterioration in characteristics and reliability.
*2: JEDEC level 3
Note: Exceeding the absolute maximum ratings even momentarily may cause a drop in product quality. Always be sure to use the
product within the absolute maximum ratingws.ww.hamamatsu.com