English
Language : 

C8225 Datasheet, PDF (1/2 Pages) Hamamatsu Corporation – Pulse generator for NMOS linear image sensor driver circuit
IMAGE SENSOR
Pulse generator for NMOS linear image sensor driver circuit
C8225 series
Pulse generator for NMOS linear image sensor
C8225
C8225 series is a pulse generator specifically designed for NMOS linear image sensor driver circuits. C8225 series provides the driver circuits
with a master start pulse and master clock pulse which can be preset by rotary switches.
C8225 series uses a quartz oscillator as the reference clock that delivers high-precision master start and clock pulses. When a separate pin connector
and socket are installed on the circuit board, C8225 series can be mounted directly on C7883/C7884/C7885 series image sensor driver circuit board.
Features
l Directly mountable on C7883/C7884/C7885 series
l Compact (compared to conventional type C4091)
l Single power supply (+5 V) operation
I Selection guide
Type No.
Description
Feature
Master start interval: 1 µs to 50 s (1-2-5 sequence)
C8225-01
For C7883/C7884 series
Master clock frequency: 62.5 kHz to 32 MHz
Has no input/output connector.
Master start interval: 1 µs to 50 s (1-2-5 sequence)
C8225-02
For C7885 series
Master clock frequency: 46.875 kHz to 24 MHz
Has no input/output connector.
Note)
1: Standard input/output connector is FAP-16-07#2 (made by Yamaichi, sold separately). Equivalent connectors are available
from other manufacturers.
2: When mounting C8225 series on a driver circuit, use a 6-pin socket (PM-1 made by MAC8) on the driver circuit and a 6-pin
plug (OY-003 made by MAC8) on C8225 series.
3: Custom products with an input/output connector pre-mounted are available on request. Please consult our sales office.
4: We welcome custom requests. Feel free to contact our sales office.
I Specifications (Ta=25 °C)
Parameter
Symbol
Supply voltage
+Vs
Current consumption *1
+Is
Operating temperature
Topr
Storage temperature
Tstg
+5 V
Condition
Min.
Typ.
Max.
Unit
+4.5
+5.0
+5.5
V
-
-
50
mA
0 to +50 *2
°C
-10 to +60 *2
°C
*1: Current consumption depends on the clock frequency.
*2: No condensation
I Timing chart
MASTER CLOCK CLK
MASTER START Start
KACCC0126EA
1