English
Language : 

G3U1084 Datasheet, PDF (2/4 Pages) GTM CORPORATION – 5A Low Dropout Positive Adjustable or Fixed-Mode Regulator
Absolute Maximum Ratings
Symbol
Parameter
Vin
DC Supply Voltage
PD
Power Dissipation
TST
Storage Temperature
TOP
Operating Junction Temperature Range
ISSUED DATE :2005/07/27
REVISED DATE :2006/03/29C
Ratings
Unit
-0.3 to 12
V
Internally Limited
-65 ~ + 150
к
0 ~ + 150
к
Electrical Characteristics
Symbol
Parameter
VREF
G3U1084ADJ
G3U1084-1.5
G3U1084-1.8
Output Voltage G3U1084-2.5
G3U1084-3.3
G3U1084-5.0
Line Regulation G3U1084XXX
G3U1084ADJ
G3U1084-1.5
G3U1084-1.8
Load Regulation
G3U1084-2.5
G3U1084-3.3
G3U1084-5.0
Vo
Dropout Voltage
ILIM
Current Limit
IMIN
Minimum Load Current
IADJ
Adjust Pin Current
IQ
Quiescent Current
Temperature Stability
Thermal Resistance
JA
Junction-to-Ambient(No
heat sink ;No air flow)
Conditions(Notes)
Io=10mA, Tj=25к, (Vin-Vout )=1.5V
Io=10mA, Tj=25к, 3.0V Vin 12V
Io=10mA, Tj=25к, 3.3V Vin 12V
Io=10mA, Tj=25к, 4.0V Vin 12V
Io=10mA, Tj=25к, 4.8V Vin 12V
Io=10mA, Tj=25к, 6.5V Vin 12V
Io=10mA, Vout+1.5V<Vin<12V, Tj=25к
Vin=3.3V, 0mA<Io<5A, TJ=25к (Note 1,2)
Vin=3.0V, 0mA<Io<5A, TJ=25к (Note 1,2)
Vin=3.3V, 0mA<Io<5A, TJ=25к (Note 1,2)
Vin=4.0V, 0mA<Io<5A, TJ=25к (Note 1,2)
Vin=5.0V, 0mA<Io<5A, TJ=25к (Note 1,2)
Vin=8.0V, 0mA<Io<5A, TJ=25к (Note 1,2)
Io=5.0A( Vout=1% Vout)
Vin-Vout=5V
Vin=5V (adjustable model)
Vin=12V, Io=10mA
Vin=12V, Io=0mA (fixed model)
Io=10mA
MIN
1.225
1.470
1.764
2.450
3.235
4.900
-
-
-
-
-
-
-
-
5.1
-
-
-
-
-
TYP
1.250
1.500
1.800
2.500
3.300
5.000
-
-
12
15
20
26
40
1.4
-
5
55
-
0.5
MAX
1.275
1.530
1.836
2.550
3.365
5.100
0.2
1
15
18
25
33
50
1.5
-
10
100
12
-
91
-
UNIT
V
V
V
V
V
V
%
%
mV
mV
mV
mV
mV
V
A
mA
uA
mA
%
к /w
JC
Thermal Resistance
Junction-to-Case
-
10
-
к /w
Note 1: See thermal regulation specifications for changes in output voltage due to heating effects. Line and load regulation are measured
at a constant junction Temperature by low duty cycle pulse testing .Load regulation is measured at the output lead =1/18” from the
package.
Note 2: Line and load regulation are guaranteed up to the maximum power dissipation of 15W. Power dissipation is determined by the
difference between input and output and the output current .Guaranteed maximum power dissipation will not be available over the
full input/output range.
G3U1084
Page: 2/4