English
Language : 

GJSBL630-660CT Datasheet, PDF (1/2 Pages) GTM CORPORATION – SCHOTTKY BARRIER RECTIFIERS
ISSUED DATE :2006/05/11
REVISED DATE :
GJSBL630CT~660CT
SCHOTTKY BARRIER RECTIFIERS
R E VE R SE VO LTAG E 3 0 V T O 6 0 V, C UR R E NT 6 A
Description
The GJSBL630CT~660CT are designed for use in low voltage, high frequency inverters, free wheeling and
polarity protection applications.
Features
Ô¦Guard ring for transient protection
Ô¦Low power loss, high efficiency
Ô¦High current capability, low VF
Ô¦High surge capacity
Package Dimensions
TO-252
REF.
A
B
C
D
E
F
S
Millimeter
Min.
Max.
6.40
6.80
5.20
5.50
6.80
7.20
2.40
3.00
2.30 REF.
0.70
0.90
0.60
0.90
REF.
G
H
J
K
L
M
R
Millimeter
Min. Max.
0.50 0.70
2.20 2.40
0.45 0.55
0
0.15
0.90 1.50
5.40 5.80
0.80 1.20
Maximum Ratings and Electrical Characteristics at Ta=25к unless otherwise specified.
Single phase, half wave, 60Hz, resistive or inductive load. For capacitive load, derate current by 20%
Parameters
Symbol GJSBL
630CT
GJSBL
635CT
Ratings
GJSBL GJSBL
640CT 645CT
GJSBL
650CT
Unit
GJSBL
660CT
V
Max. Recurrent Peak Reverse Voltage
VRRM
30
35
40
45
50
Max. RMS Voltage
VRMS
21
24.5
28
31.5
35
Max. DC Blocking Voltage
VDC
30
35
40
45
50
Max. Average Forward
@TC=95к
Rectified Current (See Fig.1)
I(AV)
6
60 V
42 V
60 V
A
Peak Surge Forward Current
8.3ms single half sine-wave superimposed
IFSM
on rated load (JEDEC METHOD)
75
A
Max. Forward Voltage @ 3A (Note 1)
VF
Max. DC Reverse Current @TJ=25к
At Rated DC Blocking Voltage @TJ=100к
IR
Typical Thermal Resistance @TC=25к (Note2)
R JC
Operating Temperature Range
Tj
Storage Temperature Range
Tstg
0.55
0.5
50
20
-55 ~ +125
-55 ~ +150
0.7
V
mA
к/W
к
к
Notes: 1. 300us Pulse Width, 2% Duty Cycle.
2. Thermal Resistance Junction to Case.
GJSBL630CT~660CT
Page: 1/2