English
Language : 

GS81282Z36GD-250I Datasheet, PDF (20/35 Pages) GSI Technology – 144Mb Pipelined and Flow Through Synchronous NBT SRAM
GS81282Z18/36(GB/GD)
AC Electrical Characteristics
Parameter
Symbol
-400
Min Max
-333
Min Max
-250
Min Max
-200
Min Max
Clock Cycle Time
tKC
2.5 — 3.0 — 4.0 — 5.0 — ns
Clock to Output Valid
tKQ
— 2.5 — 2.5 — 2.5 — 3.0 ns
Pipeline
Clock to Output Invalid
Clock to Output in Low-Z
tKQX
1.5 — 1.5 — 1.5 — 1.5 — ns
tLZ1
1.5 — 1.5 — 1.5 — 1.5 — ns
Setup time
tS
0.9 — 1.0 — 1.2 — 1.4 — ns
Hold time
tH
0.1 — 0.1 — 0.2 — 0.4 — ns
Clock Cycle Time
tKC
4.0 — 4.5 — 5.5 — 6.5 — ns
Clock to Output Valid
tKQ
— 4.0 — 4.5 — 5.5 — 6.5 ns
Flow
Through
Clock to Output Invalid
Clock to Output in Low-Z
tKQX
2.0 — 2.0 — 2.0 — 2.0 — ns
tLZ1
2.0 — 2.0 — 2.0 — 2.0 — ns
Setup time
tS
1.2 — 1.3 — 1.5 — 1.5 — ns
Hold time
tH
0.2 — 0.3 — 0.5 — 0.5 — ns
Clock HIGH Time
tKH
0.9 — 1.0 — 1.3 — 1.3 — ns
Clock LOW Time
tKL
1.1 — 1.2 — 1.5 — 1.5 — ns
Clock to Output in
High-Z
tHZ1
1.5 2.5 1.5 2.5 1.5 2.5 1.5 3.0 ns
G to Output Valid
tOE
— 2.5 — 2.5 — 2.5 — 3.0 ns
G to output in Low-Z
tOLZ1
0
—
0
—
0
—
0
— ns
G to output in High-Z
tOHZ1
— 2.5
— 2.5 — 2.5 —
3.0 ns
ZZ setup time
tZZS2
5
—
5
—
5
—
5
— ns
ZZ hold time
tZZH2
1
—
1
—
1
—
1
— ns
ZZ recovery
tZZR
20 — 20 — 20 — 20 — ns
Notes:
1. These parameters are sampled and are not 100% tested.
2. ZZ is an asynchronous signal. However, in order to be recognized on any given clock cycle, ZZ must meet the specified setup and hold
times as specified above.
Rev: 1.01 5/2017
20/34
Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
© 2015, GSI Technology