English
Language : 

GS82582DT20GE-400I Datasheet, PDF (16/27 Pages) GSI Technology – Dual Double Data Rate interface
GS82582DT20/38GE-550/500/450/400
AC Electrical Characteristics (Continued)
Parameter
Symbol
-550
Min
Max
-500
Min
Max
-450
Min
Max
-400
Min
Max
Control Input Hold Time
(R, W)
Control Input Hold Time
(BWX)
tKHIX
0.23
—
0.25
—
0.275
—
0.4
—
ns 2
tKHIX
0.18
—
0.2
—
0.22
—
0.28
—
ns 3
Data Input Hold Time
tKHDX
0.18
—
0.2
—
0.22
—
0.28
—
ns
Notes:
1. All Address inputs must meet the specified setup and hold times for all latching clock edges.
2. Control signals are R, W.
3. Control signals are BW0, BW1 and (BW2, BW3 for x36).
4. Clock phase jitter is the variance from clock rising edge to the next expected clock rising edge.
5. VDD slew rate must be less than 0.1 V DC per 50 ns for DLL lock retention. DLL lock time begins once VDD and input clock are stable.
6. After device power-up, 20s of stable input clocks (as specified by tKInit) must be supplied before reads and writes are issued.
Rev: 1.03 4/2016
16/27
Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.