English
Language : 

AK2127 Datasheet, PDF (5/6 Pages) List of Unclassifed Manufacturers – Receiver/ Demodulator for time code signals transmitted by the transmitter
Electrical Characteristics
Refering to the test circuit with generator signal
f = 77500 ± 5 Hz
pulse modulation of RF-signal from 100 % to 25 %
during modulation time t = 200 ms,
VCC1 = VCC2 = 1.4 V; VPON = 0 V; Ta = 25 °C,
unless specified otherwise
Parameter
Symbol
min.
Supply voltage 1
VCC1
2.2
Supply voltage 2
VCC2
1.2
Supply current
(VCC1 = 3.5 V)
(VCC1 = 2.2 V)
ICC11
400
ICC12
400
Supply current
ICC2
300
Supply current stand-by
(VPON = VCC1)
ICC10
Input current stand-by switch
-IPON
Input current on SR
-ISR
Output pulse duration (OPU) 1)
tOL
180
ViE1 = 3 µV, 10 mV
Output LOW-current (OPU)
IOL
100
ViE1 = 30 µV
Output LOW-voltage (OPU)
VOL
ViE1 = 30 µV; IOL = 15 µA
Output HIGH-current (OPD)
-IOH
100
ViE1 = 30 µV
Output HIGH-voltage (OPD)
VOH
1.1
ViE1 = 30 µV; -IOH =15 µA
Sensitivity
ViE1
(min. RF input for tOL ≥ 180 ms)1)
1) Test in a special application circuit without socket.
typ.
3.5
1.4
540
530
500
0.03
14
0.3
190
200
45
330
1.3
0.8
max.
Unit
5.25
V
1.8
V
690
µA
690
µA
640
µA
1
µA
20
µA
2
µA
220
ms
µA
200
mV
µA
V
1
µV
4
09/00
TFA2127