English
Language : 

70M-ODC5 Datasheet, PDF (2/2 Pages) Grayhill, Inc – DC Output Modules
DC Output Modules
SPECIFICATIONS: By Part Number
Standard and Miniature Modules
Type/Function
Grayhill Part Number
Miniature, Normally Open
Standard, Normally Open
70M-ODC5 70M-ODC5A 70M-ODC5B 70M-ODC15 70M-ODC15B 70M-ODC24 70M-ODC24B
70-ODC5 70-ODC5A 70-ODC5B 70-ODC15 70-ODC15B 70-ODC24 70-ODC24B
Specifications
Units
Maximum Line Voltage
Load Voltage Range
Max. Off-State Leakage @ Max. Line
Maximum Turn-On Time
Maximum Turn-Off Time
Typ. Power Dissipation
Clamping Voltage
Nominal Logic Voltage (Vcc)
Logic Voltage Range
Maximum Logic Supply Current
@ Nominal Vcc
Nominal Input Resistance (Rx)
Minimum Drop Out Voltage
Vdc
Vdc
mA
µSec
µSec
W/A
Vdc
Vdc
Vdc
mA
Ω
Vdc
60
3-60
1.5
20
50
1
80
5
2.5-10
14
300
1
200
4-200
0.01
75
750
1.5
360
5
2.5-9
18
220
1
60
3-60
0.01
75
500
1
80
5
2.5-10
14
300
1
60
3-60
1.5
20
50
1
80
15
10-18
9
1800
1
60
3-60
0.01
75
500
1
80
15
10-18
9
1800
1
60
3-60
1.5
20
50
1
80
24
15-30
9
2700
1
60
3-60
0.01
75
500
1
80
24
15-30
9
2700
1
G5 and OpenLine® Modules
Type/Function
Fusible, Normally Open
70G-ODC5 70G-ODC5A
Specifications
Units
Maximum Line Voltage
Vdc
Load Voltage Range
Vdc
Max. Off-State Leakage @ Max. Line mA
Maximum Turn-On Time
µSec
Maximum Turn-Off Time
µSec
Typ. Power Dissipation
W/A
Clamping Voltage
Vdc
Nominal Logic Voltage (Vcc)
Vdc
Logic Voltage Range
Vdc
Maximum Logic Supply Current
@ Nominal Vcc
mA
Nominal Input Resistance (Rx)
Ω
Minimum Drop Out Voltage
Vdc
60
3-60
1.5
20
50
1
80
5
4-6
13
150
1
200
4-200
0.01
75
750
1.5
360
5
4-6
13
150
1
Grayhill Part Number
70G-ODC5B 70G-ODC15 70G-ODC15B 70G-ODC24 70G-ODC24B
60
3-60
0.01
75
500
1
80
5
4-6
13
150
1
60
3-60
1.5
20
50
1
80
15
10-20
9
1500
1
60
3-60
0.01
75
500
1
80
15
10-20
9
1500
1
60
3-60
1.5
20
50
1
80
24
18-32
9
2700
1
60
3-60
0.01
75
500
1
80
24
18-32
9
2700
1
OpenLine® Modules
Type/Function
Dual, Fusible, Normally Open
Specifications
Maximum Line Voltage
Load Voltage Range
Max. Off-State Leakage @ Max. Line
Maximum Turn-On Time
Maximum Turn-Off Time
Typ. Power Dissipation
Clamping Voltage
Nominal Logic Voltage (Vcc)
Logic Voltage Range
Maximum Logic Supply Current
@ Nominal Vcc
Module ID Resistance to Logic
Ground
Minimum Drop Out Voltage
Units
Vdc
Vdc
mA
µSec
µSec
WA
Vdc
Vdc
Vdc
mA
Ω
Vdc
Grayhill Part Number
70L-ODC 70L-ODCA 70L-ODCB
60
3-60
1.5
20
50
1
80
5
4.5-28
7/CH
2.15K
1
200
4-200
.01
75
750
1.5
360
5
4.5-28
7/CH
2.15K
1
60
3-60
.01
75
500
1
80
5
4.5-28
7/CH
2.15K
1
Available from your local Grayhill Distributor.
For prices and discounts, contact a local Sales
Office, an authorized local Distributor or Grayhill.
I/O
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com