English
Language : 

58J8A36-01-1-10N-F Datasheet, PDF (2/3 Pages) Grayhill, Inc – Minimum Space Behind Panel 15,000 Vdc Static Protection
Keylock Rotary Switches
CIRCUITRY
REAR
VIEW
36° Angle of Throw
COMMON TERMINAL (1 POLE)
.320 ± .015 (8,13 ± 0,38) DIAMETER
CIRCLE OF TERMINAL CENTERS
18˚
POS. 1
36˚
.125 ± .015
(3,18 ± 0,38)
LOCATION OF COMMONS
2 POLES
VIEWED FROM FRONT END; SHOWN IN POSITION 1.
10
9
1
2
10 1
9
2
8
8 C2
3
C1 3
7
6
4
5
7
6
4
5
ONE POLE
TWO POLE
REAR
VIEW
60° Angle of Throw
COMMON TERMINAL (1 POLE)
.320 ± .015 (8,13 ± 0,38) DIAMETER
CIRCLE OF TERMINAL CENTERS
30˚
POS. 1
60˚
.125 ± .015
(3,18 ± 0,38)
LOCATION OF COMMONS
2 POLES
REAR
VIEW
45° Angle of Throw
COMMON TERMINAL (1 POLE)
.320 ± .015 (8,13 ± 0,38) DIAMETER
CIRCLE OF TERMINAL CENTERS
22.5˚
POS. 1
45˚
.125 ± .015
(3,18 ± 0,38)
LOCATION OF COMMONS
2 POLES
REAR
VIEW
VIEWED FROM FRONT END; SHOWN IN POSITION 1.
8
1
8
1
7
2
7
2
C2
C1
6
3
6
3
5
4
5
4
ONE POLE
TWO POLE
90° Angle of Throw
.320 ± .015 (8,13 ± 0,38)
DIAMETER CIRCLE OF
TERMINAL CENTERS
COMMON TERMINAL (1 POLE)
LOCATION OF COMMONS
2 POLES
.125 ± .015
(3,18 ± 0,38)
45˚
POS. 1
90˚
VIEWED FROM FRONT END; SHOWN IN POSITION 1.
6
1
6
1
5
2
C2
5
C1 2
4
3
ONE POLE
4
3
TWO POLE
VIEWED FROM FRONT END; SHOWN IN POSITION 1.
4
1
4
1
C2
C1
3
2
ONE POLE
3
2
TWO POLE
LOCK SPECIFICATIONS
General Characteristics
Mounting: By bushing, nut and lockwasher
Keying: All locks keyed alike except by
special order
Orientation of Keylock Switch: Lock flats
on both sides with key upright (cut side
down) in position 1.
Key Removals:
36° Throw Switch At every position or
At 0° & 180°
45° Throw Switch At every position or
At 0°, 90°, 180°, 270°
60° Throw Switch At every position or
At 0°, 180°
90° Throw Switch At every position or
At 0°, 180°
Optional pulls
Contact Grayhill
Materials & Finishes
Keys: Brass; 2 supplied
Lock Barrel & Plug: Zinc, clear chromate
Lockwasher: Steel, tin zinc plated
Mounting Nut: Steel, nickel-plated
Tumbler Plates: Brass
SWITCH SPECIFICATIONS
Electrical Characteristics
Chart is shown for non-shorting contacts and
resistive load and for the life limiting criteria
indicated below. The data for the curve was
measured at sea level, 25°C and 68% relative
humidity. Contact Grayhill for more information
if any of the following is true: life limiting
criteria are more critical than those listed;
more cycles of operation are required; a
larger make and break current is required;
the operating environment includes elevated
temperatures or reduced pressures.
300
B
200 A
100
Curve A: 220 Vac all angles
of throw.
Curve B: 115 Vac and 30
Vdc for all angles of throw.
0
0
10
20
30
CYCLES x 1000
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
Rotary
3