English
Language : 

70M-IDC5 Datasheet, PDF (1/2 Pages) Grayhill, Inc – DC Input Modules
DC Input Modules
FEATURES
• Fast Switching Polarized Input
Types
• UL, CSA, CE, TÜV Certified (TÜV
not available on OpenLine®)
• Optical Isolation
• OpenLine® and G5 Modules have
Built-in Status LED
70L-IDC
70G-IDC
70-IDC
70M-IDC
CIRCUITRY
Standard, Mini, G5
+
Rx
1
VDC
2
+VCC
3
OUTPUT
4
GROUND
5
INPUT
VOLTAGE
HYST. CIRC.
CURRENT
REGULATING
Status LED in G5 modules only.
I/O MODULE
PIN #
+
INPUT
DEVICE
1
1
–
2
2
INPUT
+
DEVICE
DC
SUPPLY
–
TERMINAL
BLOCK #
+
3
3
–
4
4
BASE
OR
RACK
OpenLine®
TYPICAL WIRING FOR MODULE 0
A
FILTER
OPTICAL
ISOLATION
HYSTERESIS
6 Vcc
7 CH. A STATUS
5 GND
FILTER
OPTICAL
ISOLATION
MODULE
B
HYSTERESIS
8 CH. B STATUS
9 MODULE ID
0Ω
SPECIFICATIONS: By Package Style
Package Style
Specifications
Units
Output Current Range
Minimum Output Breakdown Voltage
Isolation Voltage1
Vibration2
Mechanical Shock3
Storage Temp. Range
Operating Temp. Range
Warranty
mA
Vdc
Vrms
°C
°C
Std (70-)
1-50
50
4000
MIL-STD-202
MIL-STD-202
-40 to 125
-40 to 100
Lifetime
Mini (70M-)
1-50
50
4000
MIL-STD-202
MIL-STD-202
-40 to 125
-40 to 100
Lifetime
1 Field to logic and channel-to-channel if Grayhill racks are used.
2 MIL-STD-202, Method 204, 20G, 10-2000 Hz or IEC68-2-6, 0.15 mm/sec2, 10-150 Hz.
3 MIL-STD-202, Method 213, Condition F, 1500G or IEC68-2-27, 11 mS, 15g.
G5 (70G-)
1-50
50
4000
MIL-STD-202
MIL-STD-202
-40 to 125
-40 to 100
Lifetime
OL (70L-)
1-50
50
2500
IEC68-2-6
IEC68-2-27
-40 to 100
-40 to 85
Lifetime
I/O
18
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com