|
70L-OAC Datasheet, PDF (1/2 Pages) Grayhill, Inc – Transient Protection: Meets the requirements of IEEE 472, Surge Withstanding Capability Test | |||
|
AC Output Modules
FEATURES
⢠Transient Protection: Meets the
requirements of IEEE 472, âSurge
Withstanding Capability Testâ
⢠SPST, Normally Open
⢠Zero Crossing Turn-On
⢠UL, CSA, CE, TÃV Certified
⢠Optical Isolation
⢠OpenLine® and G5 Modules
Provide Replaceable 5x20 mm
Glass Fuses
⢠Built-in Status LED
⢠Lifetime Warranty
DIMENSIONS
For complete dimensional drawings, see pages
L-4 or L-5.
FUSES
G5 Fuses are 5 Amp Littelfuse part number
217005 or equivalent. OpenLine® fuses are
3.15 Amp Littelfuse part number 2173.15.
4
STANDARD, G5 PACKAGES
MINIATURE PACKAGE
3
OPENLINE PACKAGE/CH
2
1
70L-OAC
70G-OAC 70-OAC 70M-OAC
Maximum Current Versus
Ambient Temperature
The chart indicates continuous current to limit
the junction temperatures to 100°C. Information
is based on steady state heat transfer in a 2
cubic foot sealed enclosure.
CIRCUITRY
Standard, Mini, G5
LOAD 1
VAC
SNUBBER
LOAD 2
TRIGGER
CIRCUIT
-40Ë -20Ë
0
20Ë 40Ë 60Ë 80Ë 100Ë
AMBIENT TEMPERATURE (ËC)
Figure 1
OpenLine®
TYPICAL WIRING FOR MODULE 0
GND 5
Vcc 6
A
CH. A CONTROL 7
CHANNEL A
OPTICAL
ISOLATION
SNUBBER
Rx
+
3
DC CONTROL
â
4
CH. B CONTROL
MODULE ID
Fuse and status LED in G5 and OpenLine modules only.
B
2.15K
OPTICAL
ISOLATION
CHANNEL B
MODULE
SNUBBER
I/O MODULE
PIN #
1
1
LOAD
2
2
3
3
4
4
RACK
OR
BASE
LOAD
TERMINAL
BLOCK #
SPECIFICATIONS: By Package Style
Package Style
Std (70-)
Mini (70M-)
G5 (70G-)
OL (70L-)
Specifications
Load Current Range1
Maximum 1 Cycle Surge2
Maximum Turn-On-Time (60 Hz)3
Maximum Turn-Off Time (60 Hz)
Static dv/dt7
Typ. Power Dissipation
Isolation Voltage4
Vibration5
Mechanical Shock6
Storage Temp. Range
Operating Temp. Range
Warranty
Units
A rms
A rms
mSec
mSec
V/µsec
W/A
V rms
°C
°C
0.03 to 3.5
80
8.33
8.33
3000
1.0
4000
MIL-STD-202
MIL-STD-202
-40 to 125
-40 to 100
Lifetime
0.03 to 3.0
80
8.33
8.33
3000
1.0
4000
MIL-STD-202
MIL-STD-202
-40 to 125
-40 to 100
Lifetime
0.03 to 3.5
80
8.33
8.33
3000
1.0
4000
MIL-STD-202
MIL-STD-202
-40 to 125
-40 to 100
Lifetime
0.03 to 2.0/CH
30
8.33
8.33
3000
1.0
2500
IEC68-2-6
IEC68-2-27
-40 to 100
-40 to 85
Lifetime
1 See Figure 1 for derating.
2 Maximum 10 cycle surge is 50% of 1 cycle surge. Application of maximum surge may not be repeated until module temperature has returned
to its steady state value.
3 Except 70-OAC5A5 which is 200 µSec and 70-OAC5A-11, 70M-OAC5A-11, and 70G-OAC5A-11 which are 100 µSec.
4 Field to logic and channel-to-channel if Grayhill racks are used.
5 MIL-STD-202, Method 204, 20 , 10-2000 Hz or IEC68-2-6, 0.15 mm/sec2, 10-150 Hz.
6 MIL-STD-202, Method 213, Condition F, 1500G or IEC68-2-27, 11 mS, 15g.
7 Except part numbers with -L suffix which have a dv/dt rating of 200 V/µSec.
I/O
6
Grayhill, Inc. ⢠561 Hillgrove Avenue ⢠LaGrange, Illinois 60525-5997 ⢠USA ⢠Phone: 708-354-1040 ⢠Fax: 708-354-2820 ⢠www.grayhill.com
|
▷ |