70G-OAC5MA_10 Datasheet, PDF (1/2 Pages) Grayhill, Inc – Integral Three Position Manual On/Manual Off and Automatic Control Toggle Switch
Manual Override Output Modules
FEATURES
• Integral Three Position Manual
On/Manual Off and Automatic
Control Toggle Switch
• Transient Protection: Meets the
requirements of IEEE 472, “Surge
Withstanding Capability Test”
• UL, CSA Certified
• Optical Isolation
• G5 Modules Provide Replaceable
5x20 mm Glass Fuse
• Built-in Status LED
Maximum Current Versus
Ambient Temperature
The chart indicates continuous current to limit
the junction temperatures to 100°C. Information
is based on steady state heat transfer in a two
cubic foot sealed enclosure.
4
G5 PACKAGE
3
CIRCUITRY
AC Outputs
LOAD 1
VAC
SNUBBER
LOAD 2
TRIGGER
CIRCUIT
2
1
-40˚ -20˚
0
20˚ 40˚ 60˚ 80˚ 100˚
AMBIENT TEMPERATURE (˚C)
Figure 1
Rx
+
3
DC CONTROL OFF
–
4
AUTO
ON
5
DC Outputs
+ LOAD 1
VDC
VOLTAGE
SPIKE
PROTECTION
– LOAD 2
DRIVER
CIRCUIT
Rx
+
3
DC CONTROL OFF
–
4
AUTO
ON
5
Maximum Peak Surge Current
Versus Surge Duration (AC Outputs)
Information is based on a supply frequency of
60 Hz sinusoidal and a resistive or inductive
load. Application of maximum surge current
may not be repeated until the module
temperature has returned to its steady state
value.
300
200
100
80
60
40
30
STANDARD, MINI, G5
20
10
OPENLINE
6
4
3
1
1
1 2 3 4 6 10 20 40 60 100
1000
NUMBER OF FULL CYCLES AT 60 HERTZ
Figure 2
FUSES
G5 Fuses are 5 Amp Littelfuse part number
217005 or equivalent.
I/O
12
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com