GC118F Datasheet, PDF (2/4 Pages) Green Power Solutions srl – BAR CLAMP FOR HOCKEY PUK DEVICES
BAR CLAMP FOR HOCKEY PUK DEVICES
GC118…F
ORDERING INFORMATION TABLE
Clamps can be ordered using the following part numbering system
GC118 B N B A 24 F S
(1) Construction type:
(2) Insulator position:
(3) Insulator code:
(4) Bolt code:
(5) Clamping force (in kN):
(6) Special accessories
B = with double bar
S = with single bar
N = upper side
R = lower side
see table below
see table below
22
24
30
32
blank = no accessories
S = extra bar spacer
(1)
(2) (3) (4) (5)
(6)
K
K: Total thickness of the assembly to be clamped
For thicknesses S' Min < K < S Min an additional 4mm thick bar spacer is needed (see list of special accessories)
Type GC118BN…F: suggested insulator/bolt types
Allowed clearance S
Insulator choice
Bolt choice
Max height
S' Min [mm]** S Min [mm] S Max [mm]
(3)
Ins. Length [mm]
21
25
40
A
50
31
35
50
B
70
41
45
60
B
70
51
55
70
C
95
61
65
80
C
95
71
75
90
C
95
81
85
100
D
120
** with additional metal spacer only
Type GC118BR…F: suggested insulator/bolt types
Allowed clearance S
Insulator choice
(4)
Bolt Length [mm]
Z
100
A
110
B
120
C
130
D
140
E
150
F
160
T [mm]
117
127
137
147
157
167
177
Bolt choice
Max height
S' Min [mm]** S Min [mm] S Max [mm]
(3) Ins. Length [mm]
(4)
Bolt Length [mm]
T [mm]
21
25
40
A
50 ***
Z
100
129
31
35
50
A
50
A
110
139
41
45
60
A
50
B
120
149
51
55
70
B
70
C
130
159
61
65
80
B
70
D
140
169
71
75
90
C
95
E
150
179
81
85
100
C
95
F
160
189
** with additional metal spacer only
*** For S Max
Type GC118SN…F: suggested insulator/bolt types
Allowed clearance S
Insulator choice
S' Min [mm]** S Min [mm] S Max [mm]
(3)
Ins. Length [mm]
21
25
40
A
50
31
35
50
B
70
41
45
60
B
70
51
55
70
C
95
61
65
80
C
95
71
75
90
C
95
81
85
100
D
120
** with additional metal spacer only
Type GC118SR…F: suggested insulator/bolt types
Allowed clearance S
Insulator choice
S' Min [mm]** S Min [mm] S Max [mm]
(3)
Ins. Length [mm]
46
50
65
B
70
56
60
75
B
70
66
70
85
B
70
76
80
95
C
95
86
90
105
C
95
96
100
115
D
120
106
110
125
D
120
** with additional metal spacer only
Document GC118…FT001
Bolt choice
(4)
Bolt Length [mm]
Z
100
A
110
B
120
C
130
D
140
E
150
F
160
Max height
T [mm]
110
120
130
140
150
160
170
Bolt choice
(4)
Bolt Length [mm]
Z
100
A
110
B
120
C
130
D
140
E
150
F
160
Max height
T [mm]
129
139
149
159
169
179
189