English
Language : 

GOA95010 Datasheet, PDF (1/3 Pages) Green Power Solutions srl – THREE PHASE AC-SWITCH
Green Power Solutions srl
Via Venezia 34D - 10088 Volpiano (TO), Italy
Phone: +39-011-988 2251
Fax: +39-011-988 1358
Web: www.gpsemi.it
e-mail: info@gpsemi.it
GOA9xx10
THREE PHASE AC-SWITCH
Fuse protection
Blown fuse indicators with microswitch
Over temperature switches
Fan loss detection circuit
Snubber for SCR's protections
Extractible stacks for easy field service
LINE VOLTAGE UP TO 500V
RMS OUTPUT CURRENT 1000 A
Line to line voltage
GOA94010 GOA95010
400 V
500 V
Characteristic
IRMS
RMS output current
VINS (DC) Insulation voltage
Conditions
Value
1000 A
3000 V
Value
1000 A
3000 V
THYRISTOR CHARACTERISTICS
VGT
Gate trigger voltage
IGT
Gate trigger current
dV/dt
VRRM
Critical rate of rise off-state voltage
Blocking Voltage
Tj = 25 °C, V D = 5 V
Tj = 25 °C, V D = 5 V
Tj= 125 °C
Tj = 125 °C
FUSE TYPE SIBA 2068132.1100
VNF
Rated voltage
INF
Rated current
PVF
Power loss
I²t
Total I2t
At rated current
At 660V
3V
300 mA
1000 V/us
1200 V
3V
300 mA
1000 V/us
1600 V
690 V
1100 A
136 W
1200 kA2s
690 V
1100 A
136 W
1200 kA2s
MECHANICAL AND THERMAL CHARACTERISTICS
Width
Depth
Height
Mass
Ta max Max amb. op. Temp.
Tstg
Storage temperature
500 mm
500 mm
275 mm
275 mm
655 mm
655 mm
65 kg
65 kg
40 °C
40 °C
-40/60 °C -40/60 °C
Document GOA9xx10T001