GOA9xx04C
THREE PHASE AC-SWITCH
Fuse protection
Blown fuse indicators with microswitch
Over temperature switches
Fan loss detection circuit
Snubber for SCR's protections
Compact design
LINE VOLTAGE UP TO 500V
RMS OUTPUT CURRENT 450A
Line to line voltage
GOA94004C GOA95004C
400
500
Characteristic
IRMS
RMS output current
VINS (rms) Insulation voltage
Conditions
Value
450 A
3000 V
Value
450 A
3000 V
THYRISTOR TRIGGERING CHARACTERISTICS
VGT
Gate trigger voltage
Tj = 25 °C, V D = 5 V
IGT
Gate trigger current
Tj = 25 °C, V D = 5 V
dV/dt
VRRM
Critical rate of rise off-state voltage
Blocking Voltage
Tj= 125 °C
Tj = 125 °C
FUSE TYPE SIBA 2062432.630
VNF
Rated voltage
INF
Rated current
PVF
Power loss
I²t
Total I2t
At rated current
At 660V
3V
300 mA
1000 V/us
1200 V
3V
300 mA
1000 V/us
1600 V
690 V
630 A
94 W
300 kA2s
690 V
630 A
94 W
300 kA2s
MECHANICAL AND THERMAL CHARACTERISTICS
Width
Depth
Height
Mass
Ta max Max amb. op. Temp.
Tstg
Storage temperature
400 mm
340 mm
500 mm
30 Kg
40 °C
-40/ +60 °C
450 mm
340.5 mm
500 mm
30 Kg
40 °C
-40/ +60 °C