English
Language : 

SE2A Datasheet, PDF (1/2 Pages) GOOD-ARK Electronics – SURFACE MOUNT HIGH EFFICIENCY RECTIFIER
Features
For surface mounted applications
Low profile package
Built-in strain relief
Easy pick and place
Ultrafast recovery times for high efficiency
Plastic package has Underwriters Laboratory
Flammability classification 94V-0
High temperature soldering:
260 /10 seconds at terminals
SE2A THRU SE2M
SURFACE MOUNT HIGH EFFICIENCY RECTIFIER
Reverse Voltage - 50 to 1000 Volts
Forward Current - 2.0 Amperes
Mechanical Data
Case: SMA molded plastic
Terminals: Solder plated solderable per
MIL-STD-750, method 2026
Polarity: Indicated by cathode band
Weight: 0.004 ounce, 0.11 gram
Maximum Ratings and Electrical Characteristics
Ratings at 25 ambient temperature unless otherwise specified.
Resistive or inductive load.
For capacitive load, derate current by 20%.
D IM
A
B
C
D
E
F
G
H
J
K
L
M
N
P
D IM E N S IO N S
in c h e s
M in .
M ax.
M in .
0 .2 1 6
0 .2 2 6
5 .4 8
0 .1 7 6
0 .1 8 2
4 .4 8
0 .0 9 4
0 .1 0 0
2 .4 0
0 .1 7 0
0 .1 7 6
4 .3 3
0 .0 3 9
0 .0 5 5
1 .0 0
0 .0 8 0
0 .0 8 1
2 .0 3
0 .0 6 8
0 .0 8 3
1 .7 2
0 .11 2
0 .11 8
2 .8 5
0 .0 5 7
-
1 .4 4
-
0 .0 1 8
-
0 .0 1 6
-
0 .4 0
0 .1 0 9
0 .11 5
2 .7 7
0 .1 0 5
0 .1 0 7
2 .6 7
0 .0 7 8
0 .0 8 1
2 .0 0
mm
M ax.
5 .7 4
4 .6 3
2 .5 5
4 .4 8
1 .4 0
2 .0 7
2 .1 0
3 .0 0
-
0 .4 5
-
2 .9 3
2 .7 3
2 .0 5
N o te
Symbols SE2A SE2B SE2D SE2E SE2G SE2J SE2K SE2M Units
Maximum repetitive peak reverse voltage
VRRM
Maximum RMS voltage
VRMS
Maximum DC blocking voltage
VDC
Maximum average forward rectified current,
at TL=90
I(AV)
Peak forward surge current,
8.3mS single half sine-wave superimposed
on rated load (MIL-STD-750D 4066 method) T =55
IFSM
A
Maximum instantaneous forward voltage at 2.0A
VF
Maximum DC reverse current
at rated DC blocking voltage
TTA==12050
IR
A
Maximum Reverse recovery time (Note 1) TJ=25
Trr
Typical junction capacitance (Note 2)
CJ
Maximum thermal resistance (Note 3)
R JL
Operating and storage temperature range
TJ, TSTG
Notes:
(1) Reverse recovery test conditions: IF=0.5A, IR=1.0A, IRR=0.25A
(2) Measured at 1.0MHz and applied reverse voltage of 4.0 volts
(3) 8.0mm2 (0.013mm thick) land areas
50
100
200
300
400
600
800 1000 Volts
35
70
140
210
280
420
560
700 Volts
50
100
200
300
400
600
800 1000 Volts
2.0
Amps
1.00
50.0
50.0
1.30
10.0
500.0
50.0
20.0
-50 to +150
1.50
1.70
100.0
Amps
Volts
A
nS
F
/W
1