English
Language : 

FR101 Datasheet, PDF (1/3 Pages) Surge Components – 1.0 AMP. Fast Recovery Rectifiers
Features
Plastic package has Underwriters Laboratory
Flammability Classification 94V-0
Fast switching for high efficiency
Construction utilizes void-free molded plastic technique
1.0 ampere operation at TA=55 with no thermal
runaway
High temperature soldering guaranteed:
250 /10 seconds, 0.375”(9.5mm) lead length,
5 lbs. (2.3kg) tension
FR101 THRU FR107
FAST RECOVERY RECTIFIER
Reverse Voltage - 50 to 1000 Volts
Forward Current - 1.0 Ampere
Mechanical Data
Case: DO-41 molded plastic body
Terminals: Plated axial leads, solderable per
MIL-STD-750, method 2026
Polarity: Color band denotes cathode end
Mounting Position: Any
Weight: 0.012 ounce, 0.33 gram
DIMENSIONS
inches
mm
DIM
Note
Min.
Max.
Min.
Max.
A
0.165
0.205
4.2
5.2
B
0.079
0.106
2.0
2.7
C
0.028
0.034
0.71
0.86
D
1.000
-
25.40
-
Maximum Ratings and Electrical Characteristics @25 unless otherwise specified
Symbols
FR
101
Maximum repetitive peak reverse voltage
Maximum RMS voltage
Maximum DC blocking voltage
Average forward rectified current
at TA=55
Peak forward surge current
8.3mS single half sine-wave
VRRM
50
VRMS
35
VDC
50
I(AV)
IFSM
Maximum instantaneous forward voltage
IFM=1.0A, TA=25¡æ (Note 3)
VF
Maximum DC reverse current
at rated DC blocking voltage
T =25
TA=100
IR
A
Maximum reverse recovery time (Note 1)
Trr
Typical junction capacitance (Note 2)
CJ
Operating and Storage temperature range
Notes:
T, T
J STG
(1) Reverse recovery test conditions: IF=0.5A, IR=1.0A, Irr=0.25A
(2) Measured at 1.0MHz and applied reverse voltage of 4.0 volts
(3) Pulse test: pulse width 300uSec, Duty cycle 1%
FR FR FR FR
102 103 104 105
100 200 400 600
70 140 280 420
100 200 400 600
1.0
30.0
1.3
5.0
100.0
150
250
15.0
-65 to +175
FR
106
FR
107
FR
107
-STR
800 1000 1000
560 700 700
800 1000 1000
500
250
Units
Volts
Volts
Volts
Amp
Amps
Volts
A
nS
F
1