English
Language : 

HCD310 Datasheet, PDF (1/1 Pages) Golledge Electronics Ltd – 12V OCXO Low Profile
12V OCXO Low Profile
HCD310 & HCD311
Specifications
HCD310: Sine wave output
HCD311: HCMOS / TTL compatible output
36.10 (max)
27.20 (max)
0.50
0.80Ø
17.80
25.40
15.00
(max)
5.00
15.00
3
4
8.90
2
8.90
1
5
BOTTOM VIEW
PIN CONNECTION
1 Freq adjustment
2 Ref. voltage out
3 Supply
4 RF output
5 Ground & case
Scale 1:1
Features
« Temperature stability down to 50ppb
« Single 12V supply (15V or 18V optional)
« Low profile compact package
« Standard European IEC CO-08 pin-out
« Custom options available
Standard Models
The table shows the most common models. In most cases
selecting one of these models will ensure the best combina-
tion of price / performance and availability.
Freq
5.0MHz
10.0MHz
13.0MHz
50.0MHz
5.0MHz
10.0MHz
50.0MHz
Specification Ageing
per day
HCD310/BNDN ±5x10-9
HCD310/BNDN ±5x10-9
HCD310/BNDN ±5x10-9
HCD310/BNDN ±5x10-9
HCD311/BNDN ±5x10-9
HCD311/BNDN ±5x10-9
HCD311/BNDN ±5x10-9
Temperature
stability
±5x10-8 -20+60°C
±5x10-8 -20+60°C
±5x10-8 -20+60°C
±5x10-8 -20+60°C
±5x10-8 -20+60°C
±5x10-8 -20+60°C
±5x10-8 -20+60°C
Part No
MS08441
MS06244
MS08799
MA02777
MA05180
MA01432
MA05478
Parameters
Frequency range: 5.0 ~ 60.0MHz
5.0 ~ 50.0MHz
Product
HCD310 HCD311
࡯
࡯
Ageing per day (at despatch):
< ±1x10-8
Ë¿
Ë¿
< ±5x10-9
࡯
࡯
Frequency stability:
±5x10-7 per year
࡯
࡯
±1x10-7 per 5% change in VDD
࡯
࡯
Temperature stability: < ±1x10-7
Ë¿
Ë¿
< ±5x10-8
࡯
࡯
Operating temperature range:
-20 to +60°C
࡯
࡯
0 to +70°C
Ë¿
Ë¿
-20 to +70°C
Ë¿
Ë¿
Storage temperature range:
-40 to +90°C
࡯
࡯
Output waveform:
Sine wave, 1.5V p-p ±0.5V into 50⏲
࡯
HCMOS / TTL compatible
࡯
Frequency adjustment:
±1x10-5 typ (10MHz), +0.5 to +6.0V
࡯
࡯
(sufficient for 10 years ageing min)
Stabilised +6.0V supply provided
Supply voltage (VDD):
+12V (±0.5V)
࡯
࡯
+15V (±0.5V)
Ë¿
Ë¿
+18V (±0.5V)
Ë¿
Ë¿
Power consumption:
4.5W max at switch on
࡯
࡯
1.0W typ when stabilised at 25°C
࡯
࡯
Warm up:
±5x10-8 after 10mins at +25°C
࡯
࡯
Phase noise (@ 10.0MHz):
< -110dBc/Hz @ 10Hz
࡯
࡯
< -130dBc/Hz @ 100Hz
࡯
࡯
< -145dBc/Hz @ 1kHz
࡯
࡯
< -150dBc/Hz @ 10kHz
࡯
࡯
< -150dBc/Hz @ 50kHz
࡯
࡯
Shock:
IEC 68-2-27 Test Ea
50G for 11ms
࡯
࡯
Vibration:
IEC 68-2-06 Test Fc
10-55Hz, 1.5mm. 55-500Hz, 10G
࡯
࡯
࡯ Standard. ˿ Optional - Please specify required code(s) when ordering
Option
Codes
A
B
M
N
D
E
F
N
P
R
Ordering Information
Part No, or product name + option codes + frequency
eg: HCD310/BNDN 10.0MHz
HCD311/AMFP 20.0MHz
Option code X (eg HCD310/X) denotes a custom specification.
Í· See HCD210 for chassis-mounted version of HCD310
Tel: +44 1460 256 100
21 Nov 2003
Fax: +44 1460 256 101
E-mail: sales@golledge.com