English
Language : 

804-014-AA2M5-3P Datasheet, PDF (2/2 Pages) Glenair, Inc. – Cordsets For Harsh Environments
Series 804 “Mighty Mouse”
Push-Pull Quick-Disconnect
LENGTH
A MAX.
+ 2.0/-0.0 (+50.8/ -0.0)
12 IN. (300 mm.) MIN.
A
B
B MAX.
POLYAMIDE
SHIELDED JACKETED
CABLE
SERIES 804
RECEPTACLE
OVERMOLDED STRAIN
RELIEF
OPTIONAL PROTECTIVE
C
COVER WITH
POLYURETHANE WIRE
ROPE AND PULL RING
D
RIGHT ANGLE CORDSETS
C MAX.
LENGTH + 2.0/-0.0 (+50.8/ -0.0)
12 IN. (300 mm.) MIN.
MASTER
KEY
LOCATED 180°
FROM CABLE EXIT
E
MAX.
D
MAX.
How To Order Right Angle Cordsets
Insert the letter “R” after the End A or End B
Connector letter designator.
Example
Straight cable 804-014-AA4M6-4PN-48
Right Angle 804-014-ARAR4M6-4PN-48
DIMENSIONS
Shell A Max. B Max. C Max. D Max. E Max.
Size In. mm. In. mm. In. mm. In. mm. In. mm.
E
5 2.20 55.9 .44 11.2 1.500 38.10 .44 11.2 1.85 47.0
6 2.70 68.6 .49 12.4 1.500 38.10 .49 12.4 1.85 47.0
7 2.70 68.6 .57 14.5 1.700 43.18 .57 14.5 1.90 48.3
8 2.70 68.6 .60 15.2 1.750 44.45 .60 15.2 1.95 49.5
F
9 2.70 68.6 .67 17.0 1.750 44.45 .67 17.0 1.95 49.5
10 2.95 74.9 .74 18.8 1.750 44.45 .74 18.8 1.95 49.5
12 3.20 81.3 .86 21.8 1.750 44.45 .86 21.8 1.95 49.5
14 3.70 94.0 .98 24.9 1.750 44.50 .98 24.9 1.95 49.5
G
15 3.95 100.3 1.04 26.4 2.000 50.80 1.04 26.4 2.20 55.9
H
HARSH ENVIRONMENT CORDSET SPECIFICATIONS
Cable Jacket Material
Cable Shield
Thermoplastic Polyurethane, Black, UL 94 V-0 Rated
Tin-Coated Copper Braid, 90% Minimum Coverage
J
Conductors
Silver Coated Stranded Wire, TFE Insulated, Per M22759/11
BAND-IT® Shield Termination Band
Stainless Steel
Current Rating
Up to 5 AMP Continuous Duty With #22 AWG Wire
Test Voltage (Dielectric Withstanding Voltage)
500 VAC RMS sea level, 100 VAC RMS 70,000 feet
K
Insulation Resistance
200 megohms minimum
Operating Temperature
-30° C. to +105° C.
Immersion, Mated and Unmated
Solvent Resistance, Polyamide Overmold
1 meter water immersion for 1 Hour per MIL-STD-810 Method 512
Excellent Resistance to Most Solvents, Fuels, and Oils; Poor Resistance to
L
Strong Acids and Bipolar Solvents (Alcohol)
Electrical Resistance
(8 Milliohms Mated Contacts) + (Wire Resistance)
Shielding Effectiveness
50 dB minimum from 100MHz to 1000MHz.
Flammability and Toxicity (LSZH Jacket)
Toxicity Index 3.9 per NES 713
Oxygen Index 28% per ASTM D-2863
M
Smoke Index 24 per NES 711
© 2007 Glenair, Inc.
CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
G-17
Rev. 05-APR-2007
E-Mail: sales@glenair.com