801-025-AA2C5-3PA-72 Datasheet, PDF (2/2 Pages) Glenair, Inc. – Double-Start ACME Thread
Series 801 “Mighty Mouse”
Double-Start ACME Thread
LENGTH
A
A MAX.
+ 2.0/-0.0 (+50.8/ -0.0)
12 IN. (300 mm.) MIN.
B
B MAX.
POLYAMIDE
SHIELDED JACKETED SERIES 801 RECEPTACLE
CABLE
OVERMOLDED STRAIN
C
RELIEF
OPTIONAL
PROTECTIVE COVER
WITH POLYURETHANE
WIRE ROPE
D
RIGHT ANGLE CORDSETS
DIMENSIONS
LENGTH + 2.0/-0.0 (+50.8/ -0.0)
Shell A Max. B Max. C Max. D Max. E Max.
E
C MAX.
12 IN. (300 mm.) MIN.
MASTER
KEY
LOCATED 180°
FROM CABLE EXIT
Size In. mm. In. mm. In. mm. In. mm. In. mm.
5 2.000 50.80 .490 12.45 1.500 38.10 .490 12.45 1.650 41.91
6 2.500 63.50 .560 14.22 1.500 38.10 .560 14.22 1.650 41.91
7 2.500 63.50 .680 17.27 1.700 43.18 .680 17.27 1.700 43.18
F
E
MAX.
G
D
MAX.
How To Order Right Angle Cordsets
Insert the letter “R” after the End A or End B
Connector letter designator.
Example
8 2.500 63.50 .740 18.80 1.750 44.45 .740 18.80 1.750 44.45
9 2.500 63.50 .810 20.57 1.750 44.45 .810 20.57 1.750 44.45
10 2.750 69.85 .870 22.10 1.750 44.45 .870 22.10 1.750 44.45
13 3.000 76.20 .930 23.62 1.750 44.45 .930 23.62 1.750 44.45
16 3.500 88.90 1.120 28.45 1.750 44.50 1.120 28.45 1.750 44.45
17 3.750 95.25 1.180 29.97 2.000 50.80 1.180 29.97 2.000 50.80
Straight cable 801-025-AC4Z16-4PA-72
Right Angle 801-025-ARCR4Z16-4PA-72
H
SERIES 801 HARSH ENVIRONMENT CORDSET SPECIFICATIONS
J
Cable Jacket Material
Cable Shield
Conductors
BAND-IT® Shield Termination Band
Current Rating
K Test Voltage (Dielectric Withstanding Voltage)
Insulation Resistance
Operating Temperature
Immersion
L Solvent Resistance, Polyamide Overmold
Electrical Resistance
Shielding Effectiveness
M
Flammability and Toxicity (LSZH Jacket)
Thermoplastic Polyurethane, Black, UL 94 V-0 Rated
Tin-Coated Copper Braid, 90% Minimum Coverage
Silver Coated Stranded Wire, TFE Insulated, Per M22759/11
Stainless Steel
Up to 5 AMP Continuous Duty With #22 AWG Wire
500 VAC RMS sea level, 100 VAC RMS 70,000 feet
200 megohms minimum
-30° C. to +105° C.
1 meter water immersion for 1 Hour per MIL-STD-810 Method 512
Excellent Resistance to Most Solvents, Fuels, and Oils; Poor Resistance to
Strong Acids and Bipolar Solvents (Alcohol)
(8 Milliohms Mated Contacts) + (Wire Resistance)
50 dB minimum from 100MHz to 1000MHz.
Toxicity Index 3.9 per NES 713
Oxygen Index 28% per ASTM D-2863
Smoke Index 24 per NES 711
© 2007 Glenair, Inc.
CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912