AI85015
Twinax Pin Contact
Assembly Instructions
Pin Contact
100 Ohm Parallel Cable
STEP 1
1. Strip cable to dimensions shown.
Be careful not to flare braid open.
2. Pre-tin conductor and braid shield.
3. Clean the solder joint with alcohol.
Cable Shield
.250
(6.40)
Dielectric
Conductors
.150 (3.81)
.102 (2.60)
B
1. Insert cable into pin contact.
Make sure center conductor
lines up to the center pin.
STEP 2
1. Install center conductors until they
bottom-out in the contact cavity.
Inspect to ensure cable shield is visible
through the inspection hole.
2. Apply flux and solder through the
inspection hole; remove residues
and contamination with alcohol after
soldering.
1. Install M23053/5-204 or M23053/6-204
shrink tubing; cover solder area
and extend insulation by minimum
of one wire diameter.
1. Illustrates final assembly.
STEP 3
STEP 4
STEP 5
Shrink Tubing