English
Language : 

GS9090 Datasheet, PDF (42/70 Pages) Gennum Corporation – GS9090 GenLINX-R III 270Mb/s Deserializer for SDI and DVB-ASI
GS9090 Data Sheet
Table 3-13: Host Interface Description for EDH Calculation Range Registers (Continued)
Register Name
Bit
Name
Description
R/W Default
FF_LINE_START_F1 15-11
–
Not Used
–
–
Address: 1Bh
10-0
FF_LINE_START_F1[10:0] Field 1 Full Field start line data used to
R/W
0
set EDH calculation range outside of
SMPTE RP 165 values.
FF_LINE_END_F1
15-11
–
Not Used
–
–
Address: 1Ch
10-0
FF_LINE_END_F1[10:0]
Field 1 Full Field end line data used to
R/W
0
set EDH calculation range outside of
SMPTE RP 165 values.
AP_PIXEL_START_F0 15-13
–
Not Used
–
–
Address: 1Dh
12-0
AP_PIXEL_START_F0[12:0] Field 0 Active Picture start pixel data
R/W
0
used to set EDH calculation range
outside of SMPTE RP 165 values.
AP_PIXEL_END_F0
15-13
–
Not Used
–
–
Address: 1Eh
12-0
AP_PIXEL_END_F0[12:0]
Field 0 Active Picture end pixel data
R/W
0
used to set EDH calculation range
outside of SMPTE RP 165 values.
AP_PIXEL_START_F1 15-13
–
Not Used
–
–
Address: 1Fh
12-0
AP_PIXEL_START_F1[12:0] Field 1 Active Picture start pixel data
R/W
0
used to set EDH calculation range
outside of SMPTE RP 165 values.
AP_PIXEL_END_F1
15-13
–
Not Used
–
–
Address: 20h
12-0
AP_PIXEL_END_F1[12:0]
Field 1 Active Picture end pixel data
R/W
0
used to set EDH calculation range
outside of SMPTE RP 165 values.
FF_PIXEL_START_F0 15-13
–
Not Used
–
–
Address: 21h
12-0
FF_PIXEL_START_F0[12:0] Field 0 Full Field start pixel data used to
R/W
0
set EDH calculation range outside of
SMPTE RP 165 values.
FF_PIXEL_END_F0
15-13
–
Not Used
–
–
Address: 22h
12-0
FF_PIXEL_END_F0[12:0]
Field 0 Full Field end pixel data used to
R/W
0
set EDH calculation range outside of
SMPTE RP 165 values.
FF_PIXEL_START_F1 15-13
–
Not Used
–
–
Address: 23h
12-0
FF_PIXEL_START_F1[12:0] Field 1 Full Field start pixel data used to
R/W
0
set EDH calculation range outside of
SMPTE RP 165 values.
FF_PIXEL_END_F1
15-13
–
Not Used
–
–
Address: 24h
12-0
FF_PIXEL_END_F1[12:0]
Field 1 Full Field end pixel data used to
R/W
0
set EDH calculation range outside of
SMPTE RP 165 values.
28201 - 1 July 2005