English
Language : 

GS9090B_10 Datasheet, PDF (36/72 Pages) Gennum Corporation – GenLINX III 270Mb/s Deserializer for SDI
Table 3-5: Host Interface Description for EDH Flag Registers (Continued)
Register Name
Bit Name
6
FF-EDA_IN
5
FF-EDH_IN
4
AP-UES_IN
3
AP-IDA_IN
2
AP-IDH_IN
1
AP-EDA_IN
0
AP-EDH_IN
Description
Full Field Error Detected Already Flag.
Full Field Error Detected Here Flag.
Active Picture Unknown Error Status Flag.
Active Picture Internal device error Detected Already
Flag.
Active Picture Internal device error Detected Here
Flag
Active Picture Error Detected Already Flag.
Active Picture Error Detected Here Flag.
R/W
R
R
R
R
R
R
R
Default
0
0
0
0
0
0
0
Table 3-6: Host Interface Description for EDH Flag Registers
Register Name
EDH_FLAG_OUT
Address: 03h
Bit Name
15
–
14
ANC-UES
13
ANC-IDA
12
ANC-IDH
11
ANC-EDA
10
ANC-EDH
9
FF-UES
8
FF-IDA
7
FF-IDH
6
FF-EDA
5
FF-EDH
4
AP-UES
3
AP-IDA
2
AP-IDH
1
AP-EDA
0
AP-EDH
Description
Not Used
Ancillary Unknown Error Status Flag
Ancillary Internal device error Detected Already Flag.
Ancillary Internal device error Detected Here Flag.
Ancillary Error Detected Already Flag.
Ancillary Error Detected Here Flag.
Full Field Unknown Error Status Flag.
Full Field Internal device error Detected Already Flag.
Full Field Internal device error Detected Here Flag.
Full Field Error Detected Already Flag.
Full Field Error Detected Here Flag.
Active Picture Unknown Error Status Flag.
Active Picture Internal device error Detected Already
Flag.
Active Picture Internal device error Detected Here
Flag
Active Picture Error Detected Already Flag.
Active Picture Error Detected Here Flag.
R/W
–
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
Default
–
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
GS9090B GenLINX® III 270Mb/s Deserializer for SDI
Data Sheet
40749 - 5
May 2010
36 of 72