English
Language : 

GL848 Datasheet, PDF (67/85 Pages) GENESYS LOGIC – High Speed USB 2.0
GL848 High Speed USB2.0 2-in-1 Scanner Controller With Fast ADF
in 1k words
Offset E9h ……..……..………………....………..…………..….………..…..…. Default value = 8’h00
G1DWN7 G1DWN6 G1DWN5 G1DWN4 G1DWN3 G1DWN2 G1DWN1 G1DWN0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
7-0 G1DWN [7:0] Bit7~0 Registers setting for G-Channel ODD image buffer start-address. Unit is in
1k words.
Offset EAh ……..……..………………....………..…………..….………..…..…. Default value = 8’h00
G1UP15 G1UP14 G1UP13 G1UP12 G1UP11 G1UP10
R/W
R/W
R/W
R/W
R/W
R/W
G1UP9
R/W
G1UP8
R/W
7-0 G1UP[15:8]
Bit15~8 Registers setting for G-Channel ODD image buffer end-address. Unit is
in 1k words.
Offset EBh ……..……..………………....………..…………..….………..…..…. Default value = 8’h00
G1UP7
R/W
G1UP6
R/W
G1UP5
R/W
G1UP4
R/W
G1UP3
R/W
G1UP2
R/W
G1UP1
R/W
G1UP0
R/W
7-0 G1UP [7:0]
Bit7~0 Registers setting for G-Channel ODD image buffer end-address. Unit is
in 1k words.
Offset ECh ……..……..………………....………..…………..….………..…..…. Default value = 8’h00
G2DWN15 G2DWN14 G2DWN13 G2DWN12 G2DWN11 G2DWN10 G2DWN9 G2DWN8
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
7-0 G2DWN [15:8] Bit15~8 Registers setting for G-Channel EVEN image buffer start-address. Unit is
in 1k words
Offset EDh ……..……..………………....………..…………..….………..…..…. Default value = 8’h00
G2DWN7 G2DWN6 G2DWN5 G2DWN4 G2DWN3 G2DWN2 G2DWN1 G2DWN0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
7-0 G2DWN [7:0] Bit7~0 Registers setting for G-Channel EVEN image buffer start-address. Unit is
in 1k words.
Offset EEh ……..……..………………....………..…………..….………..…..…. Default value = 8’h00
G2UP15 G2UP14 G2UP13 G2UP12 G2UP11 G2UP10
R/W
R/W
R/W
R/W
R/W
R/W
G2UP9
R/W
G2UP8
R/W
©2000-2007 Genesys Logic Inc. - All rights reserved.