C8029 Datasheet, PDF (1/2 Pages) General Cable Technologies Corporation – RG 6/U Type Coaxial & 2/C 18 AWG Siamese CCTV - Cable
PRODUCT DATA SHEET
Part Number: C8029
Revision Level: 05
Date: 05/14/2012
1C 18 SBC FMPE OAS, 2C 18 AWG BC PVC,
SIAMESE FR-PVC JKT
RG 6/U Type Coaxial & 2/C 18 AWG
Siamese CCTV - Cable
A. CONSTRUCTION A (COAX)
1) CONDUCTOR:
#18 AWG Solid Bare Copper
2) INSULATION:
3) FOIL SHIELD:
4) BRAID SHIELD:
0.070” Wall Foamed Polyethylene
100% Flex Foil AMA Bonded Tape
Bare Copper Braid (95% Coverage)
B. CONSTRUCTION B (PAIR)
1) CONDUCTOR:
#18 AWG 7/.0152 Bare Copper
2) INSULATION:
0.010” Wall Polyvinyl Chloride
3) CABLE:
2 conductors (Black, Red)
DIAMETERS
0.040” nom.
0.180” nom.
0.185” nom.
0.211” nom.
0.046” nom.
0.066” nom.
0.132” nom.
C. FINAL CABLE
1) JACKET:
2) PRINT LEGEND:
0.032” Wall Polyvinyl Chloride
Major dim:
0.496” Nom
Minor dim: (coax) 0.275” Nom
Minor dim; (pair)
0.196” Nom.
CAROL (R) -- C8029 -- RG 6/U TYPE COAX – 1C 18 AWG + 2C 18 AWG CL2
(ETL) OR CM c(ETL)us 75C 3084997 — MADE IN USA (MFG CODE; MM/YY
& TRU-MARK SEQ. FT. MKGS)
D. INDUSTRY APPROVALS
UL Standards 13
National Electric Code
Type CL2 (ETL)
Article 725
UL & CSA Standards 444
National Electric Code
EU 2002/95/EC
Type CM c(ETL)us
Article 800
RoHS Compliant
E. ELECTRICAL PROPERTIES
1) TEMPERATURE:
-20C to +75C
2) SUGGESTED WORKING VOLTAGE (Vrms):
300V MAX
3) CONDUCTOR D.C. RESISTANCE A:
6.39 Ohms/1000 ft. nom. @ 20 C
4) CONDUCTOR D.C. RESISTANCE B:
6.65 Ohms/1000 ft. nom. @ 20 C
5) SHIELD RESISTANCE A:
1.90 Ohms/1000 ft. nom. @ 20 C
6) MUTUAL CAPACITANCE A:
17 pF/ft. @ 1 kHz nom.
7) CAPACITANCE B: (Conductor – Conductor)
18.0 pF/ft. @ 1kHz nom.
8) CHARACTERISTIC IMPEDANCE A:
75 Ohms @ 1 MHz nom.
9) Attenuation:
FREQ. (MHz)
dB/100 ft.
1
0.26
10
0.81
50
1.46
100
2.05
200
2.83
500
4.53
1000
6.59
Note: Data are subject to change without notice. Contact your Customer Service representative for latest information.
Rev.0: ORIGINAL FROM MANCHESTER (April 21, 2003)
Rev. 1: revise from CM to CM CL2, wall from 69 to 70 and correct DCR / GT – 03/18/2010
Rev. 2: correct spelling attention to attenuation and add cable drawing / GT (04/09/10)