English
Language : 

UGF10FCT Datasheet, PDF (1/2 Pages) General Semiconductor – ULTRAFAST SOFT RECOVERY RECTIFIER
NEW PRODUCT
NEW PRODUCT
NEW PRODUCT
UGF10FCT AND UGF10GCT
ULTRAFAST SOFT RECOVERY RECTIFIER
Reverse Voltage - 300 to 400 Volts Forward Current - 10.0 Amperes
0.405 (10.27)
0.383 (9.72)
ITO-220AB
0.140 (3.56)
DIA.
0.130 (3.30)
0.600 (15.5)
0.580 (14.5)
0.560 (14.22)
0.530 (13.46)
PIN
1
2
3
0.670 (17.2)
0.646 (16.4)
0.191 (4.85)
0.171 (4.35)
0.060 (1.52)
0.350 (8.89)
0.330 (8.38)
0.188 (4.77)
0.172 (4.36)
0.110 (2.80)
0.100 (2.54)
0.131 (3.39)
0.122 (3.08) DIA.
0.110 (2.80)
0.100 (2.54)
0.205 (5.20)
0.195 (4.95)
0.037 (0.94)
0.027 (0.69)
0.105 (2.67)
0.095 (2.41)
PIN 1
PIN 3
0.022 (0.55)
0.014 (0.36)
PIN 2
Dimensions in inches and (millimeters)
FEATURES
♦ Plastic package has Underwriters Laboratories
Flammability Classification 94V-0
♦ Ideally suited for free wheeling diode power factor
correction applications
♦ Soft recovery characteristics
♦ Excellent high temperature switching
♦ Optimized to reduce switching losses
♦ High temperature soldering guaranteed:
250°C, 0.25" (6.35mm) from case for 10 seconds
♦ Glass passivated chip junction
MECHANICAL DATA
Case: ITO-220AB molded plastic body
Terminals: Plated leads, solderable per MIL-STD-750,
Method 2026
Polarity: As marked
Mounting Position: Any
Weight: 0.08 ounce, 2.24 grams
Mounting Torque: 5 in. - lbs. max.
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25°C ambient temperature unless otherwise specified.
Maximum repetitive peak reverse voltage
Working peak reverse voltage
Maximum RMS voltage
Maximum DC blocking voltage
Maximum average forward rectified current at TC=100°C
Peak forward surge current
8.3ms single half sine-wave superimposed
on rated load (JEDEC Method) per leg
Maximum instantaneous forward voltage per leg
IF= 5A
Maximum reverse leakage current
at working peak reverse voltage
TJ=25°C
TJ=150°C
TJ=25°C
TJ=100°C
Maximum reverse recovery time per leg at IF=0.5A, IR=1.0A, Irr=0.25A
Maximum Reverse recovery time per leg at
IF=1.0A, di/dt=100A/µs, VR=30V, Irr=0.1 IRM
Maximum reverse recovery current per leg at
IF=5A, di/dt=50A/µs,VR=30V
TC=100°C
SYMBOLS
VRRM
VRWM
VRMS
VDC
I(AV)
IFSM
VF
IR
trr
trr
IRM
UGF10FCT
300
225
UGF10GCT
400
300
210
280
300
400
10
60A
1.30
1.05
10
200
35
50
3.0
Maximum stored charge per leg
IF=2A, di/dt=20A/µs, VR=30V, Irr=0.1 IRM
Typical thermal resistance from junction to case per leg
Operating junction and storage temperature range
Qrr
RΘJC
TJ, TSTG
50
6.0
-40 to +150
UNITS
Volts
Volts
Volts
Volts
Amps
Amps
Volts
µA
ns
ns
Amps
nC
°C/W
°C
4/98