English
Language : 

SS22 Datasheet, PDF (1/2 Pages) Zowie Technology Corporation – SURFACE MOUNT SCHOTTKY BARRIER RECTIFIER
SS22 THRU SS26
SURFACE MOUNT SCHOTTKY BARRIER RECTIFIER
Reverse Voltage - 20 to 60 Volts Forward Current - 2.0 Amperes
DO-214AA
0.086 (2.20)
0.077 (1.95)
0.155 (3.94)
0.130 (3.30)
0.096 (2.44)
0.084 (2.13)
0.180 (4.57)
0.160 (4.06)
0.012 (0.305)
0.006 (0.152)
0.060 (1.52)
0.030 (0.76)
0.008 (0.203)
MAX.
0.220 (5.59)
0.205 (5.21)
Dimensions in inches and (millimeters)
FEATURES
♦ Plastic package has Underwriters Laboratory
Flammability Classification 94V-0
♦ For surface mounted applications
♦ Low profile package
♦ Built-in strain relief
♦ Metal silicon junction, majority carrier conduction
♦ Low power loss, high efficiency
♦ High current capability, low forward voltage drop
♦ High surge capability
♦ For use in low voltage high frequency inverters, free
wheeling, and polarity protection applications
♦ Guardring for overvoltage protection
♦ High temperature soldering guaranteed:
250°C/10 seconds at terminals
MECHANICAL DATA
Case: JEDEC DO-214AA molded plastic body
Terminals: Solder plated, solderable per MIL-STD-750,
Method 2026
Polarity: Color band denotes cathode end
Weight: 0.003 ounce, 0.093 gram
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25°C ambient temperature unless otherwise specified.
SYMBOLS
SS22
SS23
SS24
SS25
SS26
Device marking code
S2
S3
S4
S5
S6
Maximum repetitive peak reverse voltage
Maximum RMS voltage
Maximum DC blocking voltage
Maximum average forward rectified current
at TL (SEE FIG. 1)
Peak forward surge current
8.3ms single half sine-wave superimposed on
rated load (JEDEC Method)
VRRM
VRMS
VDC
I(AV)
IFSM
20
30
40
50
60
14
21
28
35
42
20
30
40
50
60
2.0
50.0
Maximum instantaneous forward voltage at 2.0A
(NOTE 1)
Maximum DC reverse current (NOTE 1) TA=25°C
at rated DC blocking voltage
TA=100°C
Maximum thermal resistance (NOTE 2)
Operating junction temperature range
Storage temperature range
VF
IR
RΘJA
RΘJL
TJ
TSTG
0.50
0.4
10.0
75.0
17.0
-65 to +125
-65 to +150
0.70
-65 to +150
UNITS
Volts
Volts
Volts
Amps
Amps
Volts
mA
°C/W
°C
°C
NOTES:
(1) Pulse test: 300µs pulse width, 1% duty cycle
(2) P.C.B. mounted with 0.2 x 0.2” (5.0 x 5.0mm) copper pad areas
4/98