RGP25A THRU RGP25M
GLASS PASSIVATED JUNCTION FAST SWITCHING RECTIFIER
Reverse Voltage - 50 to 1000 Volts Forward Current - 2.5 Amperes
*
TED
TEN
PA
0.210 (5.3)
0.190 (4.8)
DIA.
DO-201AD
1.0 (25.4)
MIN.
0.375 (9.5)
0.285 (7.2)
0.052 (1.32)
0.048 (1.22)
DIA.
1.0 (25.4)
MIN.
FEATURES
♦ Plastic package has
Underwriters Laboratory
Flammability Classification 94V-0
♦ High temperature metallurgically bonded construction
♦ Glass passivated cavity-free junction
♦ 2.5 Ampere operation at TA=55°C with no thermal
runaway
♦ Typical IR less than 0.2µA
♦ Capable of meeting environmental standards of
MIL-S-19500
♦ Fast switching for high efficiency
♦ High temperature soldering guaranteed:
350°C/10 seconds, 0.375" (9.5mm) lead length,
5 lbs. (2.3kg) tension
Dimensions in inches and (millimeters)
*Glass-plastic encapsulation technique is covered by
Patent No. 3,996,602 and brazed-lead assembly by Patent No 3,930,306
®
MECHANICAL DATA
Case: JEDEC DO-201AD molded plastic over glass body
Terminals: Plated axial leads, solderable per MIL-STD-750,
Method 2026
Polarity: Color band denotes cathode end
Mounting Position: Any
Weight: 0.04 ounce, 1.12 grams
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25°C ambient temperature unless otherwise specified.
Maximum repetitive peak reverse voltage
Maximum RMS voltage
Maximum DC blocking voltage
Maximum average forward rectified current
0.375" (9.5mm) lead length at TA=55°C
Peak forward surge current 8.3ms single half sine-
wave superimposed on rated load (JEDEC Method)
Maximum instantaneous forward voltage at 2.5A
Maximum DC reverse current
at rated DC blocking voltage
TA=25°C
TA=125°C
Maximum full load reverse current, full cycle average
0.375" (9.5mm) lead length at TA=55°C
Maximum reverse recovery time (NOTE 1)
Typical junction capacitance (NOTE 2)
Typical thermal resistance (NOTE 3)
Operating junction and storage temperature range
RGP
SYMBOLS 25A
RGP
25B
RGP
25D
RGP
25G
RGP
25J
VRRM 50 100 200 400 600
VRMS 35 70 140 280 420
VDC 50 100 200 400 600
I(AV)
2.5
IFSM
VF
IR
IR
trr
CJ
RΘJA
TJ, TSTG
100.0
1.3
5.0
200.0
100.0
150
250
60.0
20.0
-65 to +175
NOTES:
(1) Reverse recovery test conditions: IF=0.5A, IR=1.0A, Irr=0.25A
(2) Measured at 1.0 MHz and applied reverse voltage of 4.0 Volts
(3) Thermal resistance from junction to ambient at 0.375" (9.5mm) lead length, P.C.B. mounted
RGP RGP
25K 25M UNITS
800 1000 Volts
560 700 Volts
800 1000 Volts
Amps
Amps
Volts
µA
µA
500
ns
pF
°C/W
°C
4/98