English
Language : 

BYV26D Datasheet, PDF (1/2 Pages) General Semiconductor – GLASS PASSIVATED FAST EFFICIENT RECTIFIER
BYV26D AND BYV26E
GLASS PASSIVATED FAST EFFICIENT RECTIFIER
Reverse Voltage - 800 to 1000 Volts
Forward Current - 1.0 Ampere
*
TED
TEN
PA
DO-204AP
0.034 (0.86)
0.028 (0.71)
DIA.
1.0 (25.4)
MIN.
0.150 (3.8)
0.100 (2.5)
DIA.
0.240 (6.1)
MAX.
1.0 (25.4)
MIN.
Dimensions in inches and (millimeters)
*Brazed-lead assembly is covered by Patent No. 3,930,306
FEATURES
♦ High temperature metallurgically bonded construction
♦ Glass passivated cavity-free junction
♦ Superfast recovery times for high efficiency
♦ Low forward voltage, high current capability
♦ Capable of meeting environmental standards of
MIL-S-19500
♦ Hermetically sealed package
♦ Low Leakage
♦ High surge capability
♦ Specified reverse surge capability
♦ High temperature soldering guaranteed:
350°C/10 seconds, 0.375" (9.5mm) lead length,
5 lbs. (2.3kg) tension
MECHANICAL DATA
Case: JEDEC DO-204AP solid glass body
Terminals: Plated axial leads, solderable per MIL-STD-750,
Method 2026
Polarity: Color band denotes cathode end
Mounting Position: Any
Weight: 0.02 ounce, 0.56 gram
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25°C ambient temperature unless otherwise specified.
SYMBOLS
BYV26D
BYV26E
Maximum repetitive peak reverse voltage
Maximum RMS voltage
Maximum DC blocking voltage
Minimum avalanche breakdown voltage at 100µA
Maximum average forward rectified current
0.375" (9.5mm) lead length (SEE FIG. 1)
Peak forward surge current 10ms single half
sine-wave superimposed on rated load
Maximum instantaneous forward voltage at 1.0A
TJ=25°C
TJ=175°C
Maximum DC reverse current
at rated DC blocking voltage
TA=25°C
TA=165°C
Maximum reverse recovery time (NOTE 1)
Non repetitive peak reverse energy (NOTE 2)
Typical junction capacitance (NOTE 3)
Typical thermal resistance (NOTE 4)
(NOTE 5)
Operating junction and storage temperature range
VRRM
VRMS
VDC
VBR
I(AV)
IFSM
VF
IR
trr
ERSM
CJ
RΘJA
RΘJL
TJ, TSTG
800
1000
560
700
800
1000
900
1100
1.0
30.0
2.50
1.30
5.0
150.0
75.0
10.0
15.0
70.0
16.0
-65 to +175
NOTES:
(1) Reverse recovery test conditions: IF=0.5A, IR=1.0A, Irr=0.25A
(2) Peak reverse energy measured at IR=400mA, TJ=TJ max. on inductive load, t=20µs
(3) Measured at 1.0 MHZ and applied reverse voltage of 4.0 Volts
(4) Thermal resistance from junction to ambient at 0.375" (9.5mm) lead length, mounted on P.C.B. with 0.5 x 0.5” (12 x 12mm) copper pads
(5) Thermal resistance from junction to lead at 0.375” (9.5mm) lead length with both leads attached to heatsink
UNIT
Volts
Volts
Volts
Volts
Amp
Amps
Volts
µA
ns
mj
pF
°C/W
°C
4/98