Specifications: 411 continued...
Channels/Inputs:**
• Programmable Channels 1 through 4.
• Power-limited circuitry.
• Fully supervised.
• Operation: All channels NFPA Style B (Class
B). Requires Normally Open contact to trigger.
• Normal operating voltage: 12 VDC.
• Alarm current: 3.34 mA.
• End-of-line resistor: 2.2K ohms.
• Short-circuit current: 3.8 mA per channel/
input.
**NOTE: Channels/inputs do NOT support
two-wire smoke detectors.
Form-C Relay:
• Contact rating: 2.0 amps @ 30 VDC
(resistive).
Specifications: 411
FCC Registration: OAAUSA-25431-AL-E.
Ringer Equivalence: 0.5 B.
For Canadian Applications:
IC Certificate Number: 2132 9028 A.
Ringer Equivalence Number (REN): 0.2.
Programming: A digital programming unit with
a keypad, model PRO-411, is available for
programming the 411 Series.
Operating Power: The 411 may be powered
from UL-listed control panels that output
nonresettable and power-limited 12 or 24
VDC power. The configuration of Jumper J4
determines whether 12 VDC power is to be
supplied directly to the 411 circuit board, or
24 VDC power is to be supplied and then
internally regulated down to 12 VDC.
DC Power: TB1 Terminals 1(+) and 2(–);
Terminal 3 is Earth Ground.
• J4 Jumper removed: nonresettable, and
power-limited 24 VDC (nominal) power must
be supplied at TB1 Terminals 1(+) and 2(–).
Operating voltage provided must be within
21.3 to 24.0 VDC (UL tested range: –15%,
+10%). Current requirements are 78 mA in
standby and 126 mA* while communicating.
• J4 Jumper installed: Filtered, nonresettable,
and power-limited 12 VDC (nominal) power
must be supplied at TB1 Terminals 1(+) and
2(–). Operating voltage must be within 11.2
to 12.4 VDC (UL tested range: –15%, +10%).
Current requirements are 78 mA in standby
and 126 mA* while communicating.
*NOTE: A maximum of 240 mA is possible
with all input channels active, the 411
communicating, the Programmer connected,
and Lamp Test active.
Channels/Inputs** —
TB2 Terminals 1 through 6:
• Programmable Channels 1 through 3.
• Power-limited circuitry.
• Fully supervised.
• Operation: All channels NFPA Style B (Class
B). Requires Normally Open contact to trigger.
• Normal operating voltage: 12 VDC.
• Maximum line resistance: 100 ohms per
channel.
• Alarm current: 3.34 mA.
• End-of-line resistor: 2.2K ohms, 1/2 watt (P/N
27070).
• Short circuit current: 3.8 mA per channel/
input.
**NOTE: Channels/inputs do NOT support
two-wire smoke detectors.
Gamewell-FCI
12 Clintonville Road
Northford, CT 06472-1610
Phone: 203-484-7161
Fax: 203-484-7118
www.gamewell-fci.com
A Honeywell Company
© 2009 Gamewell-FCI
Specifications and wiring information are provided for information only and are
believed to be accurate. Gamewell-FCI assumes no responsibility for their use.
Data and design are subject to change without notice. Installation and wiring
instructions shipped with the product shall always be used for actual installation.
For more information, contact Gamewell-FCI.