SCE-95 Datasheet, PDF (1/2 Pages) Gamewell-FCI by Honeywell – Signal Control Element
SCE-95
Description
Signal Control Element
The Gamewell-FCI Signal Control Elements (SCE-95) is
the interface between the Fire Alarm Control Panel's
(FACPs) analog circuits and building functions. The SCE-
95 connects to the panel via the SLC circuit. The SCE-95
provides a means to remotely locate a fully supervised cir-
cuit for the operation of signaling appliances such as
horns, strobes, and horn/strobes. The SCE-95 works with
all 600 Series analog addressable FACPs. For annuncia-
tion and feedback at the panel, Gamewell-FCI offers a Sig-
nal Control Display (SCD). The SCD is only available with
the IF632 and IF650 FACPs.
The SCE-95 is capable of switching 24 VDC. When used
as a remote signaling circuit the SCE-95 provides all the
necessary supervision of the circuit and trouble reporting
via the analog circuit.
Features
SCE-95
The Signal Control Element (SCE-95) is designed for sur-
face or flush mounting and has an integral LED which
annunciates upon device activation.
Operation
The signal control element connects to the SLC of the Fire
Alarm Control Panel (FACP) via two-wires. In its standby
mode, the SCE-95 monitors its internal circuitry for status
of the device itself and supervises the external control cir-
cuit for faults. In the event that a fault is detected, the SCE-
95 will report a trouble to the FACP.
• Compatible with the Gamewell-FCI 600 Series analog
addressable FACPs.
• Supervises and operates notification appliance circuit.
• Supervises DC power-in.
• LED annunciates activation.
• Fully supervised.
• Surface or flush mounting.
• Field programmable.
• Style four, six, or seven wiring.
• Screw terminals for field wiring connections.
• 2.0 A output..
When an event is reported to the Fire Alarm Control Panel
(FACP) that requires the activation of the SCE-95, the con-
trol panel communicates via the analog circuit to the SCE-
95 and the signaling circuit is actuated. The integral LED is
also lit for annunciation at the device.
Programming
The SCE-95 is programed by setting a single DIP switch
easily accessible on the printed circuit board. The SCE-
95’s DIP switch is used to set the address of the device.
An ISO 9000-2000 Company
SIGNALING
FM MEA
S521 APPROVED Approved 7300-1288:147
GAMEWELL-FCI
12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118
Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use.
©2007 Honeywell International Inc. All rights reserved.