FC-73 Datasheet, PDF (1/4 Pages) Gamewell-FCI by Honeywell – Fire Alarm Control Panel
FC-73
www.firecontrolinstruments.com
DESCRIPTION
The FC-73 Series Fire Alarm Control
panel is a proven, versatile conventional
zoned unit which meets the requirements
of NFPA Standard 72 for Central Station,
Supervision of vital components, modules,
functional switches, and standby batter-
ies is provided.
Protected Premises, Auxiliary, Remote
and Proprietary Supervising Station Fire
Alarm Systems. It is listed to UL Stan-
dard 864; inherently power limited, and has
all necessary circuitry to meet the UL tran-
sient immunity requirements.
The system is housed in a heavy-duty
steel enclosure finished in red, with pan-
els displaying the status of vital functions.
The surface mounted enclosure, with its
The integral Digital Alarm Communica-
tor Transmitter supports all standard re-
porting formats including:
• 3/1, 1400 Hz
• 3/1, 2300 Hz
• SK 4/2, 1400 Hz
• SIA 8
• SIA 20
• Contact ID
slim appearance (4-inch depth), is designed
to blend with any environment. The cabi-
net can house up to 7AH batteries while
the system’s power supply can maintain
batteries of up to 33 AH batteries (enclosed
in the separately available BC-1R, 1100-
0654).
Optional modules include an LCD remote
annunciator, a zone expander module used
to expand the system and a status dis-
play module which provides outputs and
control functions for each zone as well as
program access.
The many features of the FC-73 pro-
vide a cost effective approach to system FEATURES
design, and allow a great degree of flex- •Individual Zone Disconnect Switches
ibility in one enclosure. The panel provides •Supports up to six (6) Remote LCD
ten (10) Class "B" (Style B) or five (5) Class Displays
"A" (Style D) zones, expandable to twenty • Supports up to six (6) Remote LED
(20) Class "B" or ten (10) Class "A" zones Annunciators
with the addition of the ZDM-FC73 Mod- • Integral Digital Communicator
ule. The FC-73 also provides four (4) Class Transmitter
"B" (Style Y) or two (2) Class "A" (Style Z) • Expandable to Twenty (20) Class B or
notification appliance circuits.
Ten (10) Class A Zones
Standard on all FC-73 control panels are • Field Programmable Configuration
a City Master Box output, Polarity Rever- • Eight (8) Selectable/Programmable
sal signaling connections, and Integrated Output Patterns Including Temporal
DACT. The combination of a conventional Pattern Output per ANSI S3.41
fire alarm control panel with a micropro- •"Walk Test" Capability provided by the
cessor design allows for programming of LCD-FC73 optional Remote
many unique features such as time limit Annunciator
cutoff, programmed verification, pre-alarm • Programmable Alarm Verification and
delay, and cross-zoning. Individual zones
Cross-Zoning
can be assigned specific outputs and zone • Four (4) Class B or Two (2) Class A
types such as alarm, supervisory or
Notification Appliance Circuits
waterflow. In addition, up to eight (8) se- • Six (6) Amp power Supply
lectable/programmable notification appli- • Three integral progammable relays
ance circuit output patterns are available • Provides Municipal Circuit or Reverse
for alternate styles of warnings. Program- Polarity output
. ming is achieved through the LCD-FC73
annunciator module or through the Field
Configuration Program (FCP-73).
• Reverse Polarity or Municipal Circuit
output
CONVENTIONAL
FIRE ALARM
CONTROL PANEL
S1869
An ISO 9001 Company
Specifications are provided for information only, and
are not intended to be used for installation purposes
and are believed to be accurate. However, no respon-
sibility is assumed by Fire Control Instruments, Inc. for
their use. Specifications subject to change without
notice.
© 2001 All Rights Reserved
9020-0523 Rev. B
Page 1 of 4