CAB-A Datasheet, PDF (1/4 Pages) Gamewell-FCI by Honeywell – MULTIPROCESSOR-BASED
7200 SERIES
MULTIPROCESSOR-BASED
ANALOG/FCINET®/HARD-WIRE
FIRE ALARM CONTROL
DESCRIPTION
F
CThI eNFEirTe®C/oHnatrrodl
Instruments 7200
wire Fire A
Series
larm
Analog/
Control
is
multiprocessor-based and designed for commercial, indus-
trial, proprietary, central station and institutional applica-
tions. The 7200 Series may be configured as an
analog/addressable, point identified system where individ-
ual identification of initiating devices and control points are
required, a conventional hard-wired, zone-identified system,
or combination of both. It meets the requirements of NFPA
Standard 72, and is suitable for releasing device service.
The 7200 Series is field programmable to perform a wide
variety of functions. Inherently power limited, it can accom-
modate 15 units of one type with a maximum total combina-
tion of 30 units. Units are available in a wide range of
configurations.
Designed around multiprocessors that provide and control
all system functions, the 7200 Series has a powerful software
structure that affords true “distributed processing” of all sys-
tem components. The system can accommodate module
placement at either a central location, or up to fifteen (15) re-
mote locations via the FCINET® communications to provide
multiplex system features.
The FCI Listed Integrated Sensitivity Testing (LIST) pro-
gram meets all NFPA 72 requirements for testing and moni-
toring of sensor sensitivity.
The 7200 Series control has been tested for extraordinary
ambient conditions with 6,000 volt transient immunity cir-
cuits.
OPTIONAL FEATURES
FireVac®7200 Distributed Fire Alarm/ Voice
Evacuation System Operation
80-Character Alpha-numeric Display
Listed Integral Sensitivity Testing meets
NFPA 72 Testing Requirements
Drift Compensation Overcomes Effects
of Aging or Environment on Sensor
Sensitivity
“Dirty” and “Very Dirty” Sensor
Indications
Day/Night Sensor Sensitivity Setting
Class A, Style 6/7 or Class B, Style 4
Signaling Line Circuits
Selectable Analog Sensor Alarm Verification
Individually Programmable
Control and Power Relays
Switching Technology Power Supply
Interface with FireVac®III Emergency
Voice Evacuation System
Releasing Device Unit with Abort Timer
FEATURES
UL Listed to Standard 864, Category UOJZ
FCINET® (FCI Communication Network)
Control/Remote Signaling Line Circuits
Inherently Power Limited per UL 864
ADAC® Degrade Operation
Suitable for Releasing Device Service
Two Field Programmable Modes:
Front Panel/Auto-configuration
Computer
Programming Diagnostic Center
Non-volatile Data Storage
Distributed Processing
RS-232 Serial Output
Walk Test Feature
500 Event History Log
Class A, Style D or Class B, Style B
Initiating Zone Circuits
Class A, Style Z or Class B, Style Y
Individually Programmable
Notification Appliance Circuits
Alarm Verification
Dual Rate Charger
Enhanced Transient Protection
Field Expandable