English
Language : 

ASD-IL2F Datasheet, PDF (1/2 Pages) Gamewell-FCI by Honeywell – Analog, Addressable loniation Smoke Sensor
Velociti® Series
ASD-IL2F
Description
The Gamewell-FCI Velociti® Series, analog address-
able plug-in smoke sensors with integral communi-
cation provide features that surpass conventional
sensors. Sensor sensitivity can be programmed in
the control panel software. Sensitivity is continu-
ously monitored and reported to the panel. Point ID
capability allows each sensor’s address to be set,
providing exact locations for selective maintenance
when the chamber contamination reaches an unac-
ceptable level. The ASD-IL2F ionization sensor
incorporates a unique single-source, dual-chamber
design to respond quickly and dependably to a
broad range of fires.
The Velociti® Series use a communication protocol
that substantially increases the speed of communi-
cation between the sensors and certain Gamewell-
FCI analog addressable fire alarm controls. These
devices operate in a grouped fashion. If one of the
devices in the group has a status change, the
panel’s microprocessor stops the group poll and
concentrates on the single device. The net effect is
response speed up to five times greater than earlier
designs.
Ordering Information
Model
Description
ASD-IL2F Analog, Addressable Ionization Smoke
Sensor
Analog, Addressable Ionization
Smoke Sensor
Features
ASD-IL2F
• Sleek, low-profile design
• Visual rotary switch addressing
• Built-in functional test switch activated by an external
magnet
• Bicolor LEDs flash green whenever the sensor is
addressed, and light steady red on alarm*
• Optional relay, isolator, or sounder bases
• Low standby current
• Addressable-analog communication
• Stable communication technique with noise immunity
• Optional remote, single-gang LED accessory RA400Z
• Suitable for installation in ducts
Note: *Only the red LED is operative in panels that do not operate
in Velociti® mode.
Velociti® and E3 Series® are registered trademarks of Honeywell International Inc.
UL® is a registered trademark of Underwriters Laboratories Inc.
An ISO 9000-2000 Company
SIGNALING
S1913
FM MEA
APPROVED Approved
3023594 219-02-E Vol.VI 07271-0694:199
GAMEWELL-FCI
12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118
Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use.
©2008 by Honeywell International Inc. All rights reserved.
www.gamewell-fci.com
9020-0619 Rev. B3 page 1 of 2