English
Language : 

AMM-2F_13 Datasheet, PDF (1/1 Pages) Gamewell-FCI by Honeywell – Addressable Monitor Module
Velociti® Series
AMM-2F
Description
Addressable Monitor Module
The Gamewell-FCI Velociti® Series, addressable
monitor module AMM-2F is a single Style B, Class B
initiating device circuit (IDC) with a 47KW end-of-line
resistor. This module provides an address for any
device or group of devices connected to this circuit
on the signaling line circuit (SLC) of the Gamewell-
FCI addressable series fire alarm control panel. Any
initiating device with normally open (N.O.) dry con-
tacts may be made addressable when connected to
the AMM-2F module.
AMM-2F
The Velociti® Series use a communication protocol
that substantially increases the speed of communi-
cation between the sensors and certain Gamewell-
FCI analog addressable fire alarm controls. These
devices operate in a grouped fashion. If one of the
devices in the group has a status change, the
panel’s microprocessor stops the group poll and
concentrates on the single device. The net effect is
response speed up to five times greater than earlier
designs.
The AMM-2F module can be programmed to provide
a wide variety of input functions to the Gamewell-FCI
addressable series fire alarm control panels. It can
be identified as a manual station, heat detector, ple-
num detector, waterflow switch, tamper switch, N.O.
contact, smoke detector, projected beam smoke
detector, sub loop, remote zone, etc. It can also
serve as a remote system silence, system reset,
system acknowledge or drill switch. It is even possi-
ble to customize its device type to meet specific job
requirements.
The initiating device circuit of the AMM-2F can sup-
port a maximum line resistance of up to 40 ohms
allowing the use of linear heat detection devices. The
compact size facilitates the installation of the module
inside manual stations, or mounting boxes of various
types of alarm initiating devices.
Velociti® is a registered trademark of Honeywell International Inc.
UL® is a registered trademark of Underwriters Laboratories Inc.
Features
• Compact size allows easy installation
• Class B, Style B, initiating circuit
• 40 Ohm line resistance for each initiating device circuit
• Connects to any normally open dry contact device
Specifications
Supervisory Current: .000375 amps
Alarm Current:
.00060 amps
Operating Temperature: 32° to 120° F (0° to 49° C)
Relative Humidity:
10 to 93%
(non-condensing)
End-of-Line Resistance: 47K ohms
Dimensions:
1.3” L x 2.5” W x 0.5” D
(3.3 x 6.4 x 1.3 cm)
Ordering Information
Part Number
AMM-2F
Description
Addressable monitor module, single
circuit, Style B, Class B
SIGNALING
S1949
FM MEA
APPROVED Approved
3023594 227-03-E VOL IV 7300-1703:0102
GAMEWELL-FCI
12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118
Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use.
©2013 Honeywell International Inc. All rights reserved.
www.gamewell-fci.com
9020-0626 Rev. E page 1 of 1