English
Language : 

GPP5V0-20 Datasheet, PDF (5/8 Pages) Galaxy Power, Inc. – Polaris Series
Control Signal Characteristics
Specifications
Parameter
Name
P_Enable_L and
S_Enable_L
Function Controls
P_Enable_L and
S_Enable_L
Function Controls
Symbol
VENABLE LOW
VENABLE HIGH
IENABLE LOW
RENABLE LOW
RENABLE LOW
IENABLE LOW
Test Condition
Module Enabled
Module Disabled
Source Current (VENABLE = 0.8V)
Module Enabled
Module Disabled
Source Current (RENABLE = 100Ω)
Enable Controls
Primary Enable_L
Low
High or Open
Low
High or Open
Secondary Enable_L
Low
Low
High or Open
High or Open
Output Voltage
On
Off
Off
Off
Enable Circuit
Turn on Time
On >3V
Off ≤0.6V
220K
1M
IN4148
.22µF
Tantalum
To VENABLE Pin
2N7000
or
Equivalent
To (–)
Output Load Conditions
(Turn On)
Requirement
Unit
Min Max
0 0.8 V
2.5 6.0 V
– -1.0 mA
– 100 Ω
200K – KΩ
– -0.5 mA
Turn on Time
3V
VENABLE
Turn on Time for
VENABLE going Low
0.8V
Time
VOUT
Regulation Band
Time
TON
Output Voltage
Turn off Time
Turn off Time for
VENABLE going High
VENABLE
2.5V
Time
Input
Current
90% of Initial
Input Current
TOFF
Time
Polaris Series, Page 5
WWW.GALAXYPWR.COM
Part No. 99–003 Rev. 1.0