Application Notes
Control Signal Characteristics
Parameter
Symbol
Enable_L
Enable_L Source Current
Enable_L Voltage Low
Enable_L Voltage High
Enable_L Low (Turn On Delay)
Enable_L Low (Output Voltage)
Bias Current (12 Volt)
I bias
DC_OK_H High
DC_OK_H Low
Fault_H High (OVP latched)
Fault_H Low
Fault_H Source Current
(OVP latched)
Test Condition
Min Typ Max Units
VI = 5V, IO = 24A
— — 1.0 mA
— — 0.8 V
2.6 — — V
— — 10 ms
2.458 2.495 2.532 V
VI = 5V, IO = 24A
— 70 100 mA
VI = 3.43V, IO = 24A, VO = ≥2.1V 3.3 — — V
VI = 3.43V, IO = 24A, VO = ≤1.8V — — 0.8 V
VI = 3.43V, IO = 24A
3.3 —
5
V
— — 0.8 V
10 — — mA
Note: Fault–H occurs when the output voltage level is over the OVP threshold, pass transistor in the converter is shorted when
input voltage is applied, or when a difference between input to output voltage exceeds 2.4 volts with the input voltage only at 3.3V
nominal and not at 5V nominal.
Enable L: This input signal is used to enable the output
of the converter when activated (active Low). The
signal is referenced to output side (-Sense) or GND.
Enable Circuit Turn-On Time
Turn-On Time
5V
TURN ON TIME FROM
VENABLE GOING LOW
ON >5V
OFF ≤0.6V
ON/OFF
To VENABLE Pin
2N7000
or
Equivalent
To (–)
Enable
90%
VOUT
10%
0.8V
Time
Regulation Band
Time
TON
Output Load Conditions
Aries Series, Page 5
WWW.GALAXYPWR.COM
Part No. 99–001 Rev. 2.2