English
Language : 

MB15C100 Datasheet, PDF (8/28 Pages) Fujitsu Component Limited. – IF Band PLL Frequency Synthesizer
MB15C100 Series
(Continued)
Parameter
Symbol
Condition
Output current (Do)
(Charge pump type: H)
Output current (Do)
(Charge pump type: L)
High impedance cut off
current (Do)
* : VCC = 3.0, Ta = +25°C
IOH
VCC = 3 V, VOH = 2 V, Ta = +25°C
IOL
VCC = 3 V, VOL = 1 V, Ta = +25°C
IOH
VCC = 3 V, VOH = 2 V, Ta = +25°C
IOL
VCC = 3 V, VOL = 1 V, Ta = +25°C
IOFF
0V VDO VCC
Min.
—
—
—
—
—
Value
Typ.*
–6.0
6.0
–1.5
1.5
—
Max.
—
—
—
—
3
Unit
mA
mA
nA
s FUNCTIONAL DESCRIPTIONS
<A type>
Divide ratios of the internal counters can be set optionally according to customer requirements. Two different
frequencies can be selected by Div input ”H” or ”L”.
The divide ratio can be calculated using the following equation:
fVCO = {(P x N) + A} x fOSC ÷ R (A < N)
fVCO: Output frequency of external voltage controlled ocillator (VCO: up to 500 MHz)
P: Preset divide ratio of dual modulus prescaler (8/9, 16/17, 32/33)
N: Divide ratio of the main counter (5 to 4,095)
A: Divide ratio of the swallow counter (0 to 31)
fOSC: Reference oscillation frequency ( up to 26 MHz)
R: Divide ratio of the reference counter (5 to 4,095)
<B type>
Power saving control (PS)
PS
OSC
R
N.A.P
H
Active
Active
Active
L
Stop
Stop
Stop
* : Power saving current : ~ 10 µA
* : PS = “L” →Do = “Z”
LD = “H”
8