MB90350E Datasheet, PDF (72/85 Pages) Fujitsu Component Limited. – 16-bit Proprietary Microcontrollers | |||
|
◁ |
MB90350E Series
(13) I2C Timing
(TA = â40 °C to +125 °C, VCC = AVCC = 5.0 V ± 10%, fCP ⤠24 MHz, VSS = AVSS = 0 V)
Parameter
Symbol
Condition
Standard-mode Fast-mode*4
Unit
Min Max Min Max
SCL clock frequency
fSCL
0
100
0 400 kHz
Hold time for (repeated) START condition
SDA â â SCL â
tHDSTA
4.0
â¯
0.6
⯠µs
âLâ width of the SCL clock
tLOW
4.7
â¯
1.3
⯠µs
âHâ width of the SCL clock
tHIGH
4.0
â¯
0.6
⯠µs
Set-up time for a repeated START condition
SCL â â SDA â
Data hold time
SCL â â SDA â â
tSUSTA
tHDDAT
R = 1.7 kâ¦,
C = 50 pF*1
4.7
â¯
0.6
⯠µs
0
3.45*2
0
0.9*3 µs
Data set-up time
SDA â â â SCL â
tSUDAT
250*5 ⯠100*5 ⯠ns
Set-up time for STOP condition
SCL â â SDA â
tSUSTO
4.0
â¯
0.6
⯠µs
Bus free time between STOP condition and
START condition
tBUS
4.7
â¯
1.3
⯠µs
*1 : R,C : Pull-up resistor and load capacitor of the SCL and SDA lines.
*2 : The maximum tHDDAT has to meet at least that the device does not exceed the âLâ width (tLOW) of the SCL signal.
*3 : A Fast-mode I2C -bus device can be used in a Standard-mode I2C-bus system, but the requirement
tSUDAT ⥠250 ns must be met.
*4 : For use at over 100 kHz, set the machine clock to at least 6 MHz.
*5 : Refer to â⢠Note of SDA, SCL set-up timeâ.
⢠Note of SDA, SCL set-up time
SDA
Input data set-up time
SCL
6 tCP
72
|
▷ |