English
Language : 

MB39A104_08 Datasheet, PDF (5/40 Pages) Fujitsu Component Limited. – 2-ch DC/DC Converter IC with Overcurrent Protection
MB39A104
■ ABSOLUTE MAXIMUM RATINGS
Parameter
Symbol
Condition
Rating
Unit
Min
Max
Power supply voltage
VCC VCC, VCCO terminal
⎯
20
V
Output current
IO
OUT1, OUT2 terminal
⎯
60
mA
Output peak current
IOP
Duty ≤ 5% (t = 1/fOSC×Duty)
⎯
700
mA
Power dissipation
PD Ta ≤ +25 °C
⎯
740*
mW
Storage temperature
TSTG
⎯
−55
+125
°C
* : The packages are mounted on the epoxy board (10 cm × 10 cm).
WARNING: Semiconductor devices can be permanently damaged by application of stress (voltage, current,
temperature, etc.) in excess of absolute maximum ratings. Do not exceed these ratings.
■ RECOMMENDED OPERATING CONDITIONS
Parameter
Symbol
Condition
Power supply voltage
Reference voltage output current
VH output current
Input voltage
Control input voltage
Output current
Output Peak current
Oscillation frequency
Timing capacitor
Timing resistor
VH terminal capacitor
Soft-start capacitor
Short-circuit detection capacitor
Reference voltage output
capacitor
Operating ambient temperature
VCC
IREF
IVH
VINE
VDTC
VCTL
IO
IOP
fOSC
CT
RT
CVH
CS
CSCP
CREF
Ta
VCC, VCCO terminal
VREF terminal
VH terminal
−INE1, −INE2 terminal
DTC1, DTC2 terminal
CTL terminal
OUT1, OUT2 terminal
Duty ≤ 5% (t = 1/fOSC×Duty)
Overcurrent detection
by ON resistance of FET
*
⎯
⎯
VH terminal
CS1, CS2 terminal
CSCP terminal
VREF terminal
⎯
Min
7
−1
0
0
0
0
−45
−450
100
100
39
11
⎯
⎯
⎯
⎯
−30
Value
Typ
12
⎯
⎯
⎯
⎯
⎯
⎯
⎯
500
500
100
24
0.1
0.1
0.1
0.1
+25
Max
19
0
30
VCC − 0.9
VCC − 0.9
19
+45
+450
1000
1500
560
130
1.0
1.0
1.0
1.0
+85
Unit
V
mA
mA
V
V
V
mA
mA
kHz
kHz
pF
kΩ
µF
µF
µF
µF
°C
* : Refer to“ ■ SETTING THE TRIANGULAR OSCILLATION FREQUENCY”.
WARNING: The recommended operating conditions are required in order to ensure the normal operation of the
semiconductor device. All of the device’s electrical characteristics are warranted when the device is
operated within these ranges.
Always use semiconductor devices within their recommended operating condition ranges. Operation
outside these ranges may adversely affect reliability and could result in device failure.
No warranty is made with respect to uses, operating conditions, or combinations not represented on
the data sheet. Users considering application outside the listed conditions are advised to contact their
representatives beforehand.
5