s RECOMMENDED OPERATING CONDITIONS
Parameter
Supply Voltage
Input Voltage
Operating Temperature
Symbol
VCC
VI
Ta
Min.
2.7
GND
–40
Value
Typ.
3.0
–
–
Max.
5.5
VCC
+85
Unit
V
V
°C
Notes: To protect against damage by electrostatic discharge, note the following handling precautions:
– Store and transport devices in conductive containers.
– Use properly grounded workstations, tools, and equipment.
– Turn off power before inserting or removing this device into or from a socket.
– Protect leads with conductive sheet, when transporting a board mounted device.